Context: Frontal- and transverse-plane kinematics have been prospectively identified as risk factors for running-related injuries in females. The Running Readiness Scale (RRS) may allow for clinical evaluation of these kinematics.
Objectives: To determine the reliability and validity of the RRS as an assessment of frontal- and transverse-plane running kinematics.
Design: Cross-sectional study.
Setting: University research laboratory.
Patients Or Other Participants: A total of 56 novice female runners (median [interquartile range] age = 34 years [26-47 years]).
Main Outcome Measure(s): We collected 3-dimensional kinematics during running and RRS tasks: hopping, plank, step-ups, single-legged squats, and wall sit. Five clinicians assessed RRS performances 3 times each. Interrater and intrarater reliabilities of the total RRS score and individual tasks were calculated using the intraclass correlation coefficient and Fleiss κ, respectively. Pearson product moment correlation coefficients between peak joint angles measured during running and the same angles measured during RRS tasks were computed. Peak joint angles of high- and low-scoring participants were compared.
Results: Interrater and intrarater reliabilities of assessment of the total RRS scores were good (intraclass correlation coefficients = 0.75 and 0.80, respectively). Reliability of assessing individual tasks was moderate to almost perfect (κ = 0.58-1.00). Peak hip adduction, contralateral pelvic drop, and knee abduction during running were correlated with the same angles measured during hopping, step-ups, and single-legged squats (r = 0.537-0.939). Peak knee internal rotation during running was correlated with peak knee internal rotation during step-ups (r = 0.831). Runners who scored high on the RRS demonstrated less knee abduction during running (P ≤ .01).
Conclusions: The RRS may effectively assess knee abduction in novice runners, but evaluation criteria or tasks may need to be modified to effectively characterize pelvic and transverse-plane knee kinematics.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10072094 | PMC |
http://dx.doi.org/10.4085/1062-6050-404-21 | DOI Listing |
Med Sci Sports Exerc
October 2024
School of Health and Rehabilitation Sciences, The Ohio State University, Columbus, OH.
Purpose: Motion capture technology is quickly evolving providing researchers, clinicians, and coaches with more access to biomechanics data. Markerless motion capture and inertial measurement units (IMUs) are continually developing biomechanics tools that need validation for dynamic movements before widespread use in applied settings. This study evaluated the validity of a markerless motion capture, IMU, and red, green, blue, and depth (RGBD) camera system as compared to marker-based motion capture during countermovement jumps, overhead squats, lunges, and runs with cuts.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.
View Article and Find Full Text PDFSci Rep
December 2024
Gansu Provincial Ecological Environment Engineering Assessment Center, Lanzhou, 730000, People's Republic of China.
In this study, polyethylene glycol (PEG) and dextran (Dex) were chemically modified to obtain amino-functionalized PEG (PEG-(NH)) and oxidized dextran (ODex). They were subsequently reacted via -NH and -CHO groups to synthesize a macromolecular Schiff base particle. The structures, morphologies, and thermal properties of the macromolecular Schiff base particle were characterized using Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and thermogravimetry analysis (TGA).
View Article and Find Full Text PDFSci Rep
December 2024
School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China.
Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.
View Article and Find Full Text PDFSci Rep
December 2024
State Key Laboratory of Shield Machine and Boring Technology, Zhengzhou, 450001, China.
This paper presents an analytical solution derived with force method for the internal forces in the ring lining of maglev train tunnels, which are typically in a circular section and shallowly buried with low vacuum air pressure in the lining. The model incorporates the vacuum pressure induced by the differences in air pressures outside and inside the lining, and the vacuum pressure is assumed to be the active load exerting to the outside of the lining. The model assumes the vertical overburden acting on the lining is proportional to the soil depth at every particular point along the tunnel lining circumference.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!