Background: Patients with a lateral femoral wall (LFW) fracture were reported to have high rates of re-operation and complication. Although the LFW thickness was a reliable predictor of post-operative or intra-operative LFW fracture, there was a paucity of literature evaluating the critical stress distributions on the femur and screws of intertrochanteric fractures treated with dynamic hip screw (DHS). This study aimed to investigate the biomechanical performance of intertrochanteric fractures with different LFW thickness treated with DHS device.
Methods: A three-dimensional model of the proximal femur was established by computed tomography images. The intertrochanteric fracture model with three different LFW thickness (10 mm, 20.5 mm and 30 mm, respectively) was created, which was fixed by DHS. The von Mises stress on the proximal femur, lateral femoral wall, DHS and the total displacement of the device components were evaluated and compared for three different LFW thickness model.
Results: The maximum von Mises stress in the proximal fragment of the 10 and 20.5 mm model increased by 80.56% and 57.97% when compared with the 30 mm model. The peek von Mises stress around the blade entry point of the 10 mm and 20.5 mm model increased by 89.26% and 66.39% when compared with the 30 mm model. The peek von Mises in the DHS located near the junction of the barrel and side plate of each model and the 30 mm model had the smallest von Mises stress compared with the other two models. Furthermore, the maximum displacement in the 30 mm model was much smaller than that in the10mm model and 20 mm model.
Conclusions: The intertrochanteric fracture with a thinner LFW tended to have a higher risk of LFW fracture stabilized by a DHS device. Thus, the intertrochanteric fractures with a thinner LFW should not be treated by DHS alone and the intramedullary nail or an addition of trochanteric stabilization plate(TSP) was recommended.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.injury.2021.11.015 | DOI Listing |
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.
BMC Musculoskelet Disord
January 2025
Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Hebei, Shijiazhuang, 050051, P.R. China.
Background: It is known that open wedge high tibial osteotomy (OWHTO) may lead to progression of patellofemoral degeneration due to descent of the patellar height. However, the difference in patellofemoral joint (PFJ) loads with normal daily activity between uniplane and biplane osteotomies is unclear. The purpose of this study was to reveal the differences in PFJ biomechanics between uniplane and biplane OWHTO using finite element analysis (FEA).
View Article and Find Full Text PDFACS Omega
December 2024
Electronic Structure and Atomistic Dynamics Interdisciplinary Group (GEEDAI), Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Avenida dos Estados 5001, 09210-580 Santo Andre, Sao Paulo, Brazil.
Tetra-Penta-Deca-Hexa graphene (TPDH) is a new two-dimensional (2D) carbon allotrope with attractive electronic and mechanical properties. It is composed of tetragonal, pentagonal, decagonal and hexagonal carbon rings. When TPDH graphene is sliced into quasi-one-dimensional (1D) structures such as nanoribbons, it exhibits a range of behaviors, from semimetallic to semiconducting.
View Article and Find Full Text PDFFront Bioeng Biotechnol
December 2024
Department of Bioengineering, Imperial College London, London, United Kingdom.
Introduction: Up to one in five will suffer from osteoporotic vertebral fracture within their lifetime. Accurate fracture prediction poses challenges using bone mineral density (BMD) measures. Trabecular bone strains may be influenced by the underlying intervertebral disc (IVD).
View Article and Find Full Text PDFSci Rep
December 2024
Jack technology Co.,Ltd, Taizhou, 318000, China.
At present, the cutting fabric thickness of the high-ply cutter can reach 100 mm, which requires high vacuum pressure resistance performance, and the fatigue reliability of the cutter body is an important indicator of cutting performance. In this paper, the cutter body was analyzed by finite element simulation, the equivalent structural stress and Von Mises stress at key positions were calculated separately. Then, the master S-N curve method and traditional method were used to evaluate fatigue damages at key locations of the cutter body, which are compared and analyzed with the fatigue damage of measured dynamic stress.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!