Unlabelled: In this retrospective study we compared the PCa detection rates between combined (combined MRI/US fusion targeted biopsy with concurrent standard biopsy) and standard systemic, combined and targeted (component), and targeted (component) and concurrent standard (component) biopsies.
Design: Two cohorts, totaling 735 cases, were selected from the University of Wisconsin Pathology archive. 390 cases (cohort 1) were combined biopsies from 2017-2020 and 345 cases (cohort 2) were part of the standard US-guided systematic biopsies from the same period. PCa was stratified into three categories: low, intermediate, and high risks.
Results: We found that combined biopsy was significantly better than the standard biopsy in detection of PCa (65.4% vs. 51.6%, P<0.01) and intermediate-risk PCa (18.7% vs. 10.4%, P=0.05) but only slightly better at detecting high-risk PCa (26.7% vs. 23.5%, P=0.32). Further examining the biopsy results in cohort 1, we found that combined biopsy was superior to targeted biopsy (65.4% vs. 56.9%, P=0.02) or concurrent standard biopsy (65.4% vs. 52.1%, P=0.0002) in PCa detection. Combined biopsy detected significantly more high-risk PCa than concurrent standard biopsy (26.7% vs. 17.4, P=0.002), but the difference in detecting high-risk PCa between combined and targeted biopsies was not significant (26.7% vs. 22.1%, P=0.133). Similarly, the differences in detecting PCa and high-risk PCa between targeted and concurrent standard biopsies were not significant (56.9% vs. 52.1%, P=0.172 and 22.1% vs. 17.4, P=0.133, respectively). Both targeted and concurrent standard biopsies missed PCa of each risk level.
Conclusion: Combined MRI/US fusion targeted plus standard prostate biopsy is a superior technique for the detection of PCa and clinically significant PCa.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8581879 | PMC |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!