A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of Immediate Dentin Sealing Using Universal Adhesive under Simulated Pulp Pressure on Microtensile Bond Strength of Indirect Resin Composite Restorations and Dentin Permeability. | LitMetric

Objective:  The aim of this study was to investigate the effect of immediate dentin sealing (IDS) technique using universal adhesive under simulated pulp pressure on microtensile bond strength (μTBS) of indirect resin composite restorations and dentin permeability.

Materials And Methods:  Fifty extracted caries-free human third molars were used for specimens' preparation. Each molar's occlusal table was abraded flat and their roots were separated under continuous water cooling. Forty specimens were used for microtensile bond strength test (μTBST) evaluation. The μTBST specimens were randomly assigned to two groups according to the dentin sealing time; Immediate dentin sealing (IDS) and delayed dentin sealing (DDS). Each group was further subdivided into two subgroups according to the adhesive system used for dentin sealing: iBOND self-etch adhesive and GLUMA Bond Universal. All specimens were exposed to simulated pulp pressure for 1 week then restored using computer-aided design/computer-aided manufacturing (CAD/CAM) resin composite blocks. The μTBS was evaluated for all tested subgroups after 24 hours and 6 months of water storage. The remaining 10 teeth were used for the preparation of dentin discs for dentin permeability evaluation. They were divided into two groups according to type of self-etch adhesive used. Fluid filtration rate was evaluated after etching, with smear layer and after adhesive application. Results obtained were statistically analyzed using Shapiro-Wilk test and Weibull analysis.

Results:  Statistically significant difference was recorded between µTBS mean values of both IDS and DDS techniques at 24 hours and after 6 months of water storage. GLUMA Bond Universal adhesive had significantly higher bond strength compared with iBond at both IDS and DDS techniques, but both adhesives showed a significant reduction in the Weibull characteristic strength after 6 months of water storage. Significant reduction in dentin permeability was recorded by both adhesives without any significant difference between them.

Conclusions:  The IDS technique using universal adhesive in self-etch mode is an effective strategy for improving the final bond strength of CAD/CAM resin composite restorations and reducing dentin permeability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9507550PMC
http://dx.doi.org/10.1055/s-0041-1735442DOI Listing

Publication Analysis

Top Keywords

dentin sealing
24
bond strength
20
universal adhesive
16
resin composite
16
dentin permeability
16
simulated pulp
12
pulp pressure
12
microtensile bond
12
composite restorations
12
months water
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!