Aim: The Papilloplex high-risk human papillomavirus (hrHPV) test (Genefirst, Oxford, UK) is a single tube real-time HPV test which provides multiplex detection and separate identification of 14 hrHPV types. Here, we present the clinical validation of the test in SurePath samples in comparison to a clinically validated reference test, the GP5+/6+Enzyme ImmunoAssay (GP5+/6+EIA) using the VALGENT (VALidation of HPV GENotyping Tests) framework.
Methods: Clinical performance was assessed using 998 unselected, cervical screening samples enriched with 297 cytologically abnormal specimens (100 atypical squamous cells of unspecified significance, 100 low-grade squamous intraepithelial lesions, 97 high-grade squamous intraepithelial lesions). Cases were defined as women diagnosed with histologically confirmed cervical intraepithelial neoplasia two or more (≥CIN2, N=119) and controls defined as women with two subsequent negative cytology results (N=834).
Results: The Papilloplex HR-HPV test has non-inferior sensitivity for detection of cervical precancer (p=0.0001 for ≥CIN2 and p=0.0005 for ≥CIN3) and non-inferior specificity, compared with GP5+/6+EIA (pni=0.0167)). The assay also showed excellent or good agreement for overall hrHPV and nearly all individual HPV types as compared with GP5+/6+EIA/Luminex.
Conclusion: The Papilloplex HR-HPV applied on cervical specimens stored in SurePath medium fulfils the international clinical accuracy criteria for use in cervical cancer screening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9985714 | PMC |
http://dx.doi.org/10.1136/jclinpath-2021-207864 | DOI Listing |
J Virol Methods
December 2024
Scottish HPV Reference Laboratory, NHS Lothian, Royal Infirmary of Edinburgh, Little France, Edinburgh EH16 4SA, United Kingdom; HPV Research Group, University of Edinburgh, Edinburgh EH16 4TJ, United Kingdom.
Background: Self-sampling is now a key component within HPV-based cervical screening programmes to engage individuals and enhance participation. As self-sampling is relatively new, information on the influence of pre-analytical parameters such as transit-temperature and time between sampling and testing on HPV test results requires detailed investigation.
Methods: FLOQSwabs® and Evalyn Brushes® were used to assess HPV and cellular stability over a 30-week period (0w,4w,12w,30w) at 4 °C, ambient, and 37 °C.
J Clin Pathol
March 2023
Belgian Cancer Centre, Sciensano, Brussel, Belgium.
Aim: The Papilloplex high-risk human papillomavirus (hrHPV) test (Genefirst, Oxford, UK) is a single tube real-time HPV test which provides multiplex detection and separate identification of 14 hrHPV types. Here, we present the clinical validation of the test in SurePath samples in comparison to a clinically validated reference test, the GP5+/6+Enzyme ImmunoAssay (GP5+/6+EIA) using the VALGENT (VALidation of HPV GENotyping Tests) framework.
Methods: Clinical performance was assessed using 998 unselected, cervical screening samples enriched with 297 cytologically abnormal specimens (100 atypical squamous cells of unspecified significance, 100 low-grade squamous intraepithelial lesions, 97 high-grade squamous intraepithelial lesions).
Diagn Microbiol Infect Dis
September 2019
GeneFirst Ltd, Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB, UK. Electronic address:
The accurate detection and genotyping of high-risk human papillomavirus (HR-HPV) are critical for cervical cancer screening and epidemiological investigations. GeneFirst Papilloplex® HR-HPV is a new CE-IVD-marked real-time PCR test based on patented multiplex probe amplification technology. Papilloplex® HR-HPV provides the simultaneous detection and differentiation of 14 HR-HPV genotypes (16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, and 68a/b) in a single closed-tube reaction ensuring rapid, cost-effective, and contamination-free results.
View Article and Find Full Text PDFJ Clin Microbiol
March 2018
Scottish HPV Reference laboratory, Royal Infirmary of Edinburgh, NHS Lothian, Edinburgh, United Kingdom.
The use of high-risk human papillomavirus (HPV) testing for surveillance and clinical applications is increasing globally, and it is important that tests are evaluated to ensure they are fit for this purpose. In this study, the performance of a new HPV genotyping test, the Papilloplex high-risk HPV (HR-HPV) test, was compared to two well-established genotyping tests. Preliminary clinical performance was also ascertained for the detection of CIN2+ in a disease-enriched retrospective cohort.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!