Introduction: The COVID-19 pandemic has reduced the accessibility to hemoglobin A1c (HbA1c) tests required for virtual diabetes clinics. The aim was to develop and validate a user-friendly postal system for remote HbA1c monitoring.
Research Design And Methods: Validation: A total of 123 capillary blood samples from people with diabetes (PWD) needing face-to-face consultations along with healthy volunteers were measured on a point-of-care (POC) Siemens DCA Vantage Analyzer. Another sample of 5-10 drops was simultaneously collected in a K2EDTA tube (BD Microtainer) and stored for up to 12 days at room temperature for subsequent retesting. Feasibility: During October to December 2020, a total of 286 postal HbA1c kits were sent to PWD prior to their virtual consultation. These contained sample collection guidance, the necessary equipment and a feedback form. As per Packing Instruction 650 regulations, these were posted back to the diabetes center for HbA1c testing on the POC analyzer.
Results: There was a strong correlation between the first and the stored sample (R=0.978). There was a small clinically insignificant negative bias -1.53 mmol/mol (2 SD = 3.10 mmol/mol). Bland-Altman plots showed 93% of results within 2 SD. Of the 87% of returned kits, only one sample failed to be analyzed. 94% of PWD who provided feedback were happy to use the postal HbA1c system again.
Conclusions: A robust user-friendly postal HbA1c system has been created and successfully integrated into clinical practice using the existing POC equipment at the diabetes center. It provides accurate HbA1c results and is an invaluable tool for remote monitoring of HbA1c in PWD-both during and after the pandemic.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8593276 | PMC |
http://dx.doi.org/10.1136/bmjdrc-2021-002527 | DOI Listing |
Diabetes Technol Ther
November 2024
BC Children's Hospital Research Institute, Vancouver, Canada.
Structural inequities impede technology uptake in marginalized populations living with type 1 diabetes (T1D). Our objective was to describe hemoglobin A1c (HbA), time in range (TIR), and pump use to evaluate the impact of a universal funding policy for continuous glucose monitoring (CGM) across levels of deprivation in children with T1D in the Canadian province of British Columbia (BC). Patients with T1D and at least one outpatient visit after June 10, 2020 (1-year before universal CGM funding) who were enrolled in the BC Pediatric Diabetes Registry were included ( = 477).
View Article and Find Full Text PDFDiabetol Metab Syndr
September 2024
Department of Medicine, Division of Endocrinology, Diabetes Center, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Caixa Postal 20266 CEP 04022-001, Brazil.
Aims: This study aimed to investigate whether the response to adding metformin to insulin in young adults with type 1 diabetes (T1D) differs according to weight phenotype and insulin sensitivity index.
Methods: A prospective pilot study was conducted over 26 weeks in which insulin plus metformin (2 g/day) was administered to 35 individuals, ranging from normal weight (NW) to overweight (OW) to obese (OB) T1D individuals, to correlate insulin sensitivity indices and other clinical variables.
Results: At the end of the follow-up period, all groups showed an increase in the eGDR (NW: 7.
Diabetes Res Clin Pract
November 2023
ICES, Toronto, Ontario, Canada.
Aims: To compare preconception use of sodium-glucose cotransporter-2 (SGLT2i) and dipeptidyl peptidase-4 (DPP4i) inhibitors to sulfonylurea agents, and associated peri-conceptional A1c concentration, and risk of pregnancy loss and congenital anomalies.
Methods: This population-based cohort study used administrative datasets for all of Ontario, Canada, and included women eligible for free medication coverage and who achieved a recognized pregnancy from April 2007-November 2021. Exposure was a SGLT2i, DPP4i or sulfonylurea (referent) dispensed at least 90 days preconception.
Clin Chem Lab Med
January 2024
Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Ghent, Belgium.
The collection of capillary blood microsamples via finger-prick has several advantages over traditional blood collection. It is considered convenient and more patient-centric, enabling collection of the sample by the patient at her/his home with subsequent analysis in the lab following postal shipment. Determination of the diabetes biomarker HbA in self-collected microsamples to remotely monitor diabetes patients seems to be a very promising option which could eventually lead to better treatment adaptations and disease control.
View Article and Find Full Text PDFPrim Care Diabetes
August 2023
Diabetes Research Centre, University of Leicester, Leicester, UK; NIHR Leicester Biomedical Research Centre, Leicester, UK.
Aims: To implement a diabetes prevention programme in primary care METHODS: The programme was implemented for 12 months in two neighbouring towns, served by eight general practices. Practices requested a referral pathway involving an external administrator running electronic searches and sending postal invitations. If interested, people called and booked a place on the programme.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!