Recording and stimulating neuronal activity across different brain regions requires interfacing at multiple sites using dedicated tools while tissue reactions at the recording sites often prevent their successful long-term application. This implies the technological challenge of developing complex probe geometries while keeping the overall footprint minimal, and of selecting materials compatible with neural tissue. While the potential of soft materials in reducing tissue response is uncontested, the implantation of these materials is often limited to reliably target neuronal structures across large brain volumes.We report on the development of a new multi-electrode array exploiting the advantages of soft and stiff materials by combining 7-m-thin polyimide wings carrying platinum electrodes with a silicon backbone enabling a safe probe implantation. The probe fabrication applies microsystems technologies in combination with a temporal wafer fixation method for rear side processing, i.e. grinding and deep reactive ion etching, of slender probe shanks and electrode wings. The wing-type neural probes are chronically implanted into the entorhinal-hippocampal formation in the mouse forrecordings of freely behaving animals.Probes comprising the novel wing-type electrodes have been realized and characterized in view of their electrical performance and insertion capability. Chronic electrophysiologicalrecordings of the entorhinal-hippocampal network in the mouse of up to 104 days demonstrated a stable yield of channels containing identifiable multi-unit and single-unit activity outperforming probes with electrodes residing on a Si backbone.The innovative fabrication process using a process compatible, temporary wafer bonding allowed to realize new Michigan-style probe arrays. The wing-type probe design enables a precise probe insertion into brain tissue and long-term stable recordings of unit activity due to the application of a stable backbone and 7-m-thin probe wings provoking locally a minimal tissue response and protruding from the glial scare of the backbone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1741-2552/ac39b7 | DOI Listing |
Sci Rep
January 2025
Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates.
This study advances microfluidic probe (MFP) technology through the development of a 3D-printed Microfluidic Mixing Probe (MMP), which integrates a built-in pre-mixer network of channels and features a lined array of paired injection and aspiration apertures. By combining the concepts of hydrodynamic flow confinements (HFCs) and "Christmas-tree" concentration gradient generation, the MMP can produce multiple concentration-varying flow dipoles, ranging from 0 to 100%, within an open microfluidic environment. This innovation overcomes previous limitations of MFPs, which only produced homogeneous bioreagents, by utilizing the pre-mixer to create distinct concentration of injected biochemicals.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Physics and Astronomy, University of California, Riverside, CA, USA.
The floating phase, a critical incommensurate phase, has been theoretically predicted as a potential intermediate phase between crystalline ordered and disordered phases. In this study, we investigate the different quantum phases that arise in ladder arrays comprising up to 92 neutral-atom qubits and experimentally observe the emergence of the quantum floating phase. We analyze the site-resolved Rydberg state densities and the distribution of state occurrences.
View Article and Find Full Text PDFClin Epigenetics
January 2025
Translational Gastroenterology and Liver Unit, John Radcliffe Hospital, Headley Way, Headington, Oxford, OX3 9DU, UK.
Background: IgG4-related cholangitis (IgG4-SC) and primary sclerosing cholangitis (PSC) are chronic fibro-inflammatory hepatobiliary conditions, with genetic, environmental, and immunologic risk factors, in which epigenetic alterations may provide insights into pathophysiology and novel biomarkers. This study is the first to assess methylation signatures in IgG4-SC.
Results: Whole blood DNA methylation profiling and genotyping was performed in 264 individuals; 47 with IgG4-SC, 65 with PSC, 64 with ulcerative colitis (UC), and 88 healthy controls.
We develop fs laser-fabricated asymmetric couplers and zig-zag arrays consisting of single- and two-mode waveguides with bipartite Kerr nonlinearity in borosilicate (BK7) glass substrates. The fundamental mode ( orbital) is near resonance with the neighboring higher-order orbital, causing efficient light transfer at low power. Due to Kerr nonlinearity, the coupler works as an all-optical switch between and orbitals.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, P. R. China.
Urinalysis is one of the predominant tools for clinical testing owing to the abundant composition, sufficient volume, and non-invasive acquisition of urine. As a critical component of routine urinalysis, urine protein testing measures the levels and types of proteins, enabling the early diagnosis of diseases. Traditional methods require three separate steps including strip testing, protein/creatinine ratio measurement, and electrophoresis respectively to achieve qualitative, quantitative, and classification analyses of proteins in urine with long time and cumbersome operations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!