A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Graded Microstructured Flexible Pressure Sensors with High Sensitivity and an Ultrabroad Pressure Range for Epidermal Pulse Monitoring. | LitMetric

Graded Microstructured Flexible Pressure Sensors with High Sensitivity and an Ultrabroad Pressure Range for Epidermal Pulse Monitoring.

ACS Appl Mater Interfaces

Department of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems Ministry of Education, Chongqing University, Chongqing 400044, P. R. China.

Published: November 2021

Precisely detecting epidermal pulse waves with pressure sensors is crucial for pulse-based personalized health-monitoring technologies. However, developing a pressure sensor that simultaneously demonstrates high sensitivity and an ultrabroad pressure range and a convenient fabrication process for large-scale production is a considerable challenge. Herein, by utilizing a commercial conductive fabric (CF) and a silica gel film, we develop a high-performance pressure sensor (HPPS) for the monitoring of human physiological signals. Based on convenient turnover formwork technology, the silica gel film was fabricated by replicating the microstructure of the sandpaper surface. This microstructure and the plain weave structure on the CF surface together provide a sharp increase in the contact-separation area and structural compressibility, which are beneficial for the enhancement of output performance. Made of these two materials, the graded microstructured HPPS holds high sensitivity (4.5 mV/Pa), an ultrabroad pressure range (0-30 kPa), a wide working frequency bandwidth (up to 35 Hz), decent stability (>50,000 cycles), and a simple fabrication process that is suitable for large-scale production. Given these noticeable features, the developed HPPS not only succeeds in precisely detecting subtle pulse waves on various positions of different people but can also objectively capture changes in cardiovascular parameters caused by exercise training at different intensities in real time. These findings exhibit the enormous potential application of HPPS in tracking an individual's health status and comprehensively evaluating exercise intensity.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.1c17318DOI Listing

Publication Analysis

Top Keywords

high sensitivity
12
ultrabroad pressure
12
pressure range
12
graded microstructured
8
pressure sensors
8
sensitivity ultrabroad
8
epidermal pulse
8
precisely detecting
8
pulse waves
8
pressure sensor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!