Purpose: To analyze the structure of the choriocapillaris in healthy eyes by using averaged en face images acquired using swept source optical coherence tomography angiography and to examine the changes in the macular profile in relation to age, sex, axial length, and choroidal thickness.

Methods: This prospective, cross-sectional study included 81 eyes of 81 subjects without ophthalmologic or systemic diseases who underwent a full ophthalmologic examination, including 3 × 3-mm macular optical coherence tomography angiography. Four to nine choriocapillaris en face images were registered and averaged. The averaged images were then binarized and analyzed.

Results: The averaged choriocapillaris images showed a continuous capillary meshwork, whereas the unaveraged images had a granular appearance. The mean total area and size of flow voids were 0.99 ± 0.20 mm2 and 567.8 ± 201.5 μm2, respectively, and these values correlated positively with age (p = 0.002, R = 0.336 and p = 0.026, R = 0.247, respectively). Age-related gains in the mean total area and flow void size were 4.20 × 10-3 mm2 and 3.07 μm2 per year, respectively. However, the mean total area and flow void size had no significant correlation with axial length, subfoveal choroidal thickness, or sex.

Conclusions: Multiple averaged en face swept source optical coherence tomography angiography is more effective than a single optical coherence tomography angiography scan for better visualizing the choriocapillaris. The total area and size of flow voids within a 3 × 3-mm macular area positively correlated with age. This technique can be useful for investigating the changes arising in macular diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8592481PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0259880PLOS

Publication Analysis

Top Keywords

optical coherence
20
coherence tomography
20
tomography angiography
20
total area
16
axial length
12
age sex
8
sex axial
8
length subfoveal
8
subfoveal choroidal
8
choroidal thickness
8

Similar Publications

Purpose: To identify optical coherence tomography (OCT)-based imaging biomarkers that can localize focal leakage points without fluorescein angiography in central serous chorioretinopathy (CSC).

Methods: This retrospective case-control study analyzed 119 consecutive patients (123 eyes) with CSC between April 2018 and February 2024, comprising 66 eyes with focal-leakage type and 57 eyes with diffuse-leakage type. We assessed leakage sites using OCT, and the proportions of OCT findings were compared between focal- and diffuse-leakage types.

View Article and Find Full Text PDF

Drusen Regression Following Macular Hole Surgery: A Case Report.

Retin Cases Brief Rep

January 2025

Herbert Wertheim College of Medicine, Florida International University, Miami, Florida, USA.

Purpose: To report a case of drusen regression following pars plana vitrectomy with internal limiting membrane peel (ILMP) in a patient with a full-thickness macular hole and dry age-related macular degeneration (AMD).

Methods: A 67-year-old gentleman presented in April 2024 with a full-thickness macular hole in OS and intermediate dry AMD OU. The patient underwent pars plana vitrectomy, ILMP, and an injection of sulfur hexafluoride gas for macular hole repair in OS.

View Article and Find Full Text PDF

Purpose: Predicting long-term anatomical responses in neovascular age-related macular degeneration (nAMD) patients is critical for patient-specific management. This study validates a generative deep learning (DL) model to predict 12-month posttreatment optical coherence tomography (OCT) images and evaluates the impact of incorporating clinical data on predictive performance.

Methods: A total of 533 eyes from 513 treatment-naïve nAMD patients were analyzed.

View Article and Find Full Text PDF

Broadband coherent Fourier scatterometry: A two-pulse approach.

Rev Sci Instrum

January 2025

Optics Research Group, Imaging Physics Department, Delft University of Technology, Van der Waalsweg 8, 2628 CH Delft, The Netherlands.

We demonstrate a broadband implementation of coherent Fourier scatterometry (CFS) using a supercontinuum source. Spectral information can be resolved by splitting the incident field into two pulses with a variable delay and interfering them at the detector after interaction with the sample, bearing similarities with Fourier-transform spectroscopy. By varying the time delay between the pulses, a collection of diffraction patterns is captured in the Fourier plane, thereby obtaining an interferogram for every camera pixel.

View Article and Find Full Text PDF

Background And Objective: Sickle cell disease (SCD) is a vascular disease that may affect the retina. This study aimed to evaluate differences in average velocity (AV, mm/s), blood flow (BF, μL/min) and vessel diameter (VD, μm) from the temporal retinal arcades in SCD compared to healthy eyes using Doppler optical coherence tomography (DOCT).

Patients And Methods: A cross-sectional study was conducted between 2021 and 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!