Background: As nonoperative treatment of Neer type II distal clavicle fractures is associated with nonunion rates up to 33%, operative treatment is frequently advocated. However, evidence is lacking regarding which operative treatment to perform and whether this is superior to nonoperative treatment in terms of functional outcome and complication rate.

Purpose: (1) To evaluate which surgical technique in the treatment of Neer type II distal clavicle fractures is optimal with regard to patient-reported outcomes and union and complication rates. (2) To review nonoperatively treated patients.

Study Design: Systematic review; Level of evidence, 4.

Methods: A systematic review of the literature and meta-analysis were performed on January 27, 2021, in PubMed, Embase, CENTRAL, CINAHL/EBSCO, Web of Science/Clarivate Analytics, and SPORTDiscus/EBSCO. The search included all studies regarding nonoperative and operative treatment of Neer type II distal clavicle fractures with a minimum of 20 patients and follow-up of 12 months. The primary and secondary outcomes were patient-reported outcome measures at 12 months and union, complication, and revision rates.

Results: A total of 59 articles were included involving 2284 patients. Coracoclavicular fixation, hook plate, transacromial pins, alternative plate, tension band wire/K-wire, a combination of surgical techniques, and a nonoperative group were described. Hook plates showed lower Constant-Murley scores as compared with coracoclavicular fixation (standard mean difference, -0.77; 95% CI, -1.26 to -0.28; = .002). However, no significant difference was seen when the hook plate was compared with the locking plate and tension band wire/K-wire groups, and no significant difference in union rate was seen among all operative treatment groups. Operatively treated patients had significantly higher union rates than patients treated nonoperatively (standard mean difference: 0.05; 95% CI, 0.01 to 0.37; = .004).

Conclusion: Patients treated with hook plates showed significantly lower Constant-Murley scores and higher complication and revision rates as compared with those treated with coracoclavicular fixation, without differences in union rate. Higher Constant-Murley scores were seen in those patients with supplemental coracoclavicular fixation when using locking. Nonoperatively treated patients showed good functional outcome despite the 31% nonunion rate, although future studies are necessary to substantiate this conclusion. When using a locking plate, additional craniocaudal fixation showed significant better functional outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1177/03635465211053336DOI Listing

Publication Analysis

Top Keywords

neer type
16
type distal
16
distal clavicle
16
clavicle fractures
16
operative treatment
16
coracoclavicular fixation
16
union rate
12
systematic review
12
treatment neer
12
functional outcome
12

Similar Publications

Distal augmentation in unstable distal clavicle fractures: a retrospective cohort study of 101 cases.

Arch Orthop Trauma Surg

January 2025

The Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123, Ta Pei Road, Niao Sung Dist, Kaohsiung, Taiwan.

Introduction: The optimal management strategy for unstable distal clavicular fractures remains controversial. Recent studies on plate techniques have reported good-to-excellent outcomes with no serious complications. The questions are that: (1) Does the use of wire augmentation with locking plate in distal part (distal wire augmentation) reduce radiographic loss of reduction (RLOR) and get earlier bony union in distal clavicular fractures? (2) Which fixation methods are associated with a higher incidence of acromioclavicular (AC) joints arthritis or subluxation? We collected and analyzed clinical studies on different plate fixation methods for unstable fractures to identify the best surgical modality.

View Article and Find Full Text PDF

A new classification for dislocated and displaced proximal humeral fractures.

J Orthop Surg Res

January 2025

Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-minamimachi, Chuo-ku, Kobe, 650-0047, Japan.

Background: Although the Neer and AO/OTA classifications have been widely accepted, observer reliability studies of these two classifications have questioned their reliability and reproducibility to date. We developed an entirely new classification, the Mitsuzawa classification, for dislocated and displaced proximal humeral fractures and tested all three classifications for their intra- and interobserver reliability.

Methods: Two experienced shoulder surgeons and two orthopedic residents independently evaluated the Xray (xR) values of 100 proximal humeral fractures (PHFs).

View Article and Find Full Text PDF

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

J Orthop Surg Res

January 2025

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.

Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

View Article and Find Full Text PDF

Application of 3D printing technology in preoperative planning and treatment of proximal humerus fractures: a retrospective study.

BMC Musculoskelet Disord

November 2024

Department of Orthopedics, Nantong Haimen People's Hospital, No. 1201 Beijing Road, Haimen Street, Haimen District, Nantong City, Jiangsu Province, 226100, P.R. China.

Article Synopsis
  • The study investigates the use of 3D printing technology in treating proximal humeral fractures, comparing its effectiveness to traditional surgical methods.
  • Results show that the 3D printing group experienced shorter surgery times, increased accuracy in implant placement, and better functional outcomes at 6 months post-surgery.
  • Patients in the 3D printing group also reported lower pain levels and fewer complications related to bone growth compared to those who underwent conventional surgery.
View Article and Find Full Text PDF

Osteosynthesis using Scorpion plate for neer type V distal clavicle fracture.

BMC Musculoskelet Disord

November 2024

Department of Orthopaedic Surgery, Ashikaga Red Cross Hospital, 284-1 Yobe-cho, Ashikaga-shi, 326-0843, Tochigi, Japan.

Background: Neer type V distal clavicle fractures are considered the most unstable fracture type and are characterized by the disruption of continuity between the coracoclavicular (C-C) ligaments and proximal or distal bone fragments. However, owing to the rarity of such fractures, there is currently no universally accepted surgical procedure for their treatment. Recently, the scorpion plate, an anatomical, non-locking, pre-contoured plate with two grasping arms to fix the distal or inferior clavicular fragments, was introduced.

View Article and Find Full Text PDF