Purpose: This work was set out to investigate the feasibility of dose reduction in SPECT myocardial perfusion imaging (MPI) without sacrificing diagnostic accuracy. A deep learning approach was proposed to synthesize full-dose images from the corresponding low-dose images at different dose reduction levels in the projection space.
Methods: Clinical SPECT-MPI images of 345 patients acquired on a dedicated cardiac SPECT camera in list-mode format were retrospectively employed to predict standard-dose from low-dose images at half-, quarter-, and one-eighth-dose levels. To simulate realistic low-dose projections, 50%, 25%, and 12.5% of the events were randomly selected from the list-mode data through applying binomial subsampling. A generative adversarial network was implemented to predict non-gated standard-dose SPECT images in the projection space at the different dose reduction levels. Well-established metrics, including peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and structural similarity index metrics (SSIM) in addition to Pearson correlation coefficient analysis and clinical parameters derived from Cedars-Sinai software were used to quantitatively assess the predicted standard-dose images. For clinical evaluation, the quality of the predicted standard-dose images was evaluated by a nuclear medicine specialist using a seven-point (- 3 to + 3) grading scheme.
Results: The highest PSNR (42.49 ± 2.37) and SSIM (0.99 ± 0.01) and the lowest RMSE (1.99 ± 0.63) were achieved at a half-dose level. Pearson correlation coefficients were 0.997 ± 0.001, 0.994 ± 0.003, and 0.987 ± 0.004 for the predicted standard-dose images at half-, quarter-, and one-eighth-dose levels, respectively. Using the standard-dose images as reference, the Bland-Altman plots sketched for the Cedars-Sinai selected parameters exhibited remarkably less bias and variance in the predicted standard-dose images compared with the low-dose images at all reduced dose levels. Overall, considering the clinical assessment performed by a nuclear medicine specialist, 100%, 80%, and 11% of the predicted standard-dose images were clinically acceptable at half-, quarter-, and one-eighth-dose levels, respectively.
Conclusion: The noise was effectively suppressed by the proposed network, and the predicted standard-dose images were comparable to reference standard-dose images at half- and quarter-dose levels. However, recovery of the underlying signals/information in low-dose images beyond a quarter of the standard dose would not be feasible (due to very poor signal-to-noise ratio) which will adversely affect the clinical interpretation of the resulting images.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8940834 | PMC |
http://dx.doi.org/10.1007/s00259-021-05614-7 | DOI Listing |
Acta Radiol
December 2024
Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey.
Background: Triple rule-out computed tomography angiography (CTA) provides imaging of the coronary arteries, pulmonary arteries, and thoracic aorta filled with contrast material (CM) to exclude or diagnose the pathologies of these three systems. Although dual rule-out adapted to exclude aortic and pulmonary pathologies. Iodinated CM may result in contrast-induced nephropathy, which lengthens hospital stay.
View Article and Find Full Text PDFInt J Gen Med
December 2024
Department of Tuberculosis, The Affiliated Hospital of Zunyi Medical University, Zunyi, Guizhou, People's Republic of China.
Purpose: Tuberculosis meningitis (TBM) has emerged as the most lethal type of disease. The prognosis of meningitis is often related to disease severity and early therapeutic intervention.
Methods: Patients were screened for primary TBM and received a quadruple regimen comprising isoniazid (standard dose of 300 mg/day and high dose of 600 mg/day), rifampin, ethambutol, and pyrazinamide.
Abdom Radiol (NY)
December 2024
Department of Radiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Shandong Lung Cancer Institute, Shandong Institute of Neuroimmunology, Jinan, China.
Objectives: To assess the impact of artificial intelligence iterative reconstruction algorithms (AIIR) on image quality with phantom and clinical studies.
Methods: The phantom images were reconstructed with the hybrid iterative algorithm (HIR: Karl 3D-3, 5, 7, 9) and AIIR (grades 1-5) algorithm. Noise power spectra (NPS), task transfer functions (TTF) were measured, and additionally sharpness was assessed using a "blur metric" procedure.
Acad Radiol
December 2024
Recep Tayyip Erdogan University, Department of Radiology, Rize, Turkey (M.S., E.K., M.B., F.B.C.). Electronic address:
Rationale And Objectives: Magnetic resonance imaging (MRI) is a vital tool for diagnosing neurological disorders, frequently utilising gadolinium-based contrast agents (GBCAs) to enhance resolution and specificity. However, GBCAs present certain risks, including side effects, increased costs, and repeated exposure. This study proposes an innovative approach using generative adversarial networks (GANs) for virtual contrast enhancement in brain MRI, with the aim of reducing or eliminating GBCAs, minimising associated risks, and enhancing imaging efficiency while preserving diagnostic quality.
View Article and Find Full Text PDFAcad Radiol
December 2024
Department of Radiology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China (H.Z., Q.C., W.M., J.Y., S.W., G.T., J.X., H.J., H.Y., L.Z.). Electronic address:
Rationale And Objectives: To comprehensively assess the feasibility of low-dose computed tomography (LDCT) using deep learning image reconstruction (DLIR) for evaluating pulmonary subsolid nodules, which are challenging due to their susceptibility to noise.
Materials And Methods: Patients undergoing both standard-dose CT (SDCT) and LDCT between March and June 2023 were prospectively enrolled. LDCT images were reconstructed with high-strength DLIR (DLIR-H), medium-strength DLIR (DLIR-M), adaptive statistical iterative reconstruction-V level 50% (ASIR-V-50%), and filtered back projection (FBP); SDCT with FBP as the reference standard.