Setting: Dhulikhel Hospital, Kathmandu University Hospital, Kathmandu, Nepal.
Objectives: 1) To report the incidence of health-care-associated infections (HAIs), 2) to compare demographic, clinical characteristics and hospital outcomes in those with and without HAIs; and 3) to verify bacterial types in HAI and community-acquired infections (CAIs) among inpatients with invasive devices and/or surgical procedures.
Design: This was a cohort study using secondary data (December 2017 to April 2018).
Results: Of 1,310 inpatients, 908 (69.3%) had surgical procedures, 125 (9.5%) had invasive devices and 277 (21.1%) both. Sixty-six developed HAIs (incidence = 5/100 patient admissions, 95% CI 3.9-6.3). Individuals with HAIs had a 5.5-fold higher risk of longer hospital stays (⩾7 days) and a 6.9-fold risk of being in intensive care compared to the surgical ward. Unfavourable hospital exit outcomes were higher in those with HAIs (4.5%) than in those without (0.9%, = 0.02). The most common HAI bacteria ( = 70) were (44.3%), spp. (22.9%) and spp. (11.4%). Of 98 CAIs with 41 isolates, (36.6%), (22.0%) and methicillin-resistant (14.6%) were common.
Conclusion: We found relatively low incidence of HAIs, which reflects good infection prevention and control standards. This study serves as a baseline for future monitoring and action.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575378 | PMC |
http://dx.doi.org/10.5588/pha.21.0039 | DOI Listing |
Mikrochim Acta
January 2025
Indian Institute of Technology (BHU), Varanasi, 221005, India.
In the modern age, half of the population is facing various chronic illnesses due to glucose maintenance in the body, major causes of fatality and inefficiency. The early identification of glucose plays a crucial role in medical treatment and the food industry, particularly in diabetes diagnosis. In the past few years, non-enzymatic electrochemical glucose sensors have received a lot of interest for their ability to identify glucose levels accurately.
View Article and Find Full Text PDFLab Chip
January 2025
Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
Wearable microfluidic sweat sensors could play a major role in the future of monitoring health and wellbeing. Sweat contains biomarkers to monitor health and hydration status, and it can provide information on drug intake, making it an interesting non-invasive alternative to blood. However, sweat is not created in excess, and this requires smart sweat collection strategies to handle small volumes.
View Article and Find Full Text PDFJ Cardiovasc Surg (Torino)
February 2025
Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.
Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.
View Article and Find Full Text PDFAdv Healthc Mater
January 2025
Department of Physical Sciences, Indian Institute of Science Education and Research Mohali, Knowledge City, Sector 81, SAS Nagar, Manauli, 140306, India.
Fluoropolymer alone, as an alternative to lead-based piezoelectric materials, has shown multiple challenges to develop useful sensors for solving real-world problems such as photoacoustic, ultrasound pulse echo, and other non-destructive testing. This work demonstrates the fabrication of high frequency and wide bandwidth transducers with fluoropolymer and highly polarizing cubic single crystal Barium titanate (BaTiO) ceramic composite for high resolution in-vivo photo-acoustic and ultrasound imaging. For transducer fabrication, a customized bio-compatible nanocomposite sensor film of PVDF-TrFE (Polyvinylidene fluoride trifluoroethylene)/BaTiO (BTO) is synthesized by drop and dry in heating-cum-electro-poling system for advancing polarization, crystallinity, and higher charge generation.
View Article and Find Full Text PDFMueller matrix polarization measurement technique, as a non-invasive and label-free, provides comprehensive optical information on polarization-related and structural characteristics of the measured target. It has been widely applied in biomedical, agricultural, and industrial fields. However, the traditional time-division modulation Mueller matrix measurement method requires multiple measurements, which suffers from long measurement time and susceptibility to cumulative errors from moving parts.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!