A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Placing a New Filter before Removing Embolized Nonconical Filter: A Report of 13 Cases. | LitMetric

Objectives: Permanent filter placement may result in numerous complications. Filter removal is recommended if there are no risks of pulmonary embolism. This study aimed to explore the feasibility of placing a new filter when the embolized nonconical filter is removed.

Methods: This study included patients who had received a new filter between 2018 and 2019 before the nonconical filters were removed. Patient characteristics, new filter types, thrombus interception rate, filter removal rate, feasibility, and safety were analyzed retrospectively. Feasibility was defined as the successful placement of new filters and the removal of the nonconical filters. Safety was defined as the absence of symptomatic pulmonary embolism and inferior vena cava hemorrhage after removing the nonconical filters, as well as the successful removal of new filters without symptomatic pulmonary embolism.

Results: The average indwelling period of the nonconical filters was 29 (range, 17-30) days among the 13 patients. The removal rate of the nonconical filters was 100%. Five patients (38.5%) received new Denali filters, one (7.7%) received a new Celect filter, and 7 (53.8%) received new temporary filters. Thrombi were intercepted in 10 of the patients (76.9%). The removal rate of the replaced new filters was 100%. No rupture or shifting of the new filters occurred. No symptomatic pulmonary embolism was found after the removal of both the nonconical filters and the new filters. The patients were followed up for 3 months after the surgeries, and the inferior vena cavae of 12 (92.3%) patients were patent, and no new embolic events were found.

Conclusions: Placing a new replacement filter before removal of the embolized nonconical filter may be a feasible approach to prevent pulmonary embolism. Both the nonconical filter and the new filter could be removed subsequently after the thrombi were treated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2021.09.036DOI Listing

Publication Analysis

Top Keywords

nonconical filters
24
nonconical filter
16
pulmonary embolism
16
filter
13
filters
13
embolized nonconical
12
filter removal
12
removal rate
12
symptomatic pulmonary
12
nonconical
10

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!