Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the performance of a dual-energy (DE) calcium removal software based on a modified three-material decomposition algorithm in assessing the stenosis of the internal carotid artery (ICA) in comparison with mixed images using digital subtraction angiography (DSA) as the reference standard.
Methods: Forty-six patients (38 men; 67±8 years old), including 154 calcified ICA segments C1-C2 (59), C3-C5 (63), C6 (24), and C7 (8), were recruited in this retrospective study. Mixed images and virtual non-calcium (VNCa) images using the modified dual-energy computed tomography (DECT) algorithm were reconstructed. The differences between VNCa and DSA images vs. mixed and DSA images of degree of stenosis were compared. The intraclass correlation coefficient (ICC) was used for assessing the agreement between VNCa, mixed images, and DSA.
Results: The degree of stenosis differed significantly between mixed and DSA images in the C3-C5 (30%±17.9% vs. 23.0%±16.9%, p = 0.026) and C6 (38.3%±15.4% vs. 28.5%±13.3%, p = 0.023) segments. The stenosis of VNCa images showed no significant difference with DSA images in all segments (all p > 0.05). The ICCs between VNCa and DSA images (0.86-0.97) were higher than those between the mixed and DSA images (0.68-0.96) in all segments.
Conclusion: The performance of a modified three-material decomposition DECT algorithm for calcium removal in ICA stenosis evaluation, particularly for the C3-C5 and C6 ICA segments, was promising.