A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sequential Injection System for Analysis of Degree Brix, Orthophosphate and pH in Raw Sugarcane Juice Applicable to Sugar Industry. | LitMetric

Sequential Injection System for Analysis of Degree Brix, Orthophosphate and pH in Raw Sugarcane Juice Applicable to Sugar Industry.

Molecules

Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.

Published: October 2021

This work presents, for the first time, a new sequential injection analysis (SIA) method to simultaneously analyze degree Brix, orthophosphate and pH in raw cane juice. These key parameters relate to price of harvested sugarcane and quality of cane juice for sugar production. The SIA system employed two detectors: the first detector is a diode-array spectrophotometer, equipped with a regular flow cell, for measurements of degree Brix and orthophosphate. Quantitative of degree Brix (°Bx; ca. % (/) sucrose) was based on manipulation of the schlieren effect at the interface between plugs of sample and water. Orthophosphate analysis was carried out based on the molybdenum blue method with significant reduction in consumption of the reagents. Compensation of the schlieren effect from sucrose for determination of orthophosphate was achieved by using a dual-wavelength spectrometric detection. Second detector is a pH-sensing device, called ion-selective field-effect transistors (ISFET). The ISFET is based on the current through the ISFET arising according to the H concentration in solution. Our developed SIA system provides linear calibration graphs fitting for purpose in analysis of sugarcane juice (pH: 0-14, °Bx: 1.0-7.0 and PO: 20-200 mg L). Simultaneous analysis of sugarcane juice for pH, °Bx and PO is carried out within 5 min (12 sample per h). Precision of SIA system is acceptable (RSD < 3%). Our SIA system gave quantitative results insignificantly different, as compared with conventional methods for analysis of pH, °Bx and PO in sugarcane juice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587050PMC
http://dx.doi.org/10.3390/molecules26216484DOI Listing

Publication Analysis

Top Keywords

degree brix
16
sugarcane juice
16
sia system
16
brix orthophosphate
12
sequential injection
8
orthophosphate raw
8
cane juice
8
analysis sugarcane
8
analysis
6
juice
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!