A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Short-Term Outcomes of Colorectal Stenting Using a Low Axial Force Self-Expandable Metal Stent for Malignant Colorectal Obstruction: A Japanese Multicenter Prospective Study. | LitMetric

(1) Background: Endoscopic colorectal stenting with high technical success and safety is essential in discussing the oncological outcomes for the management of malignant colorectal obstruction. Mechanical properties of self-expandable metal stents are usually considered to affect clinical outcomes. (2) Methods: A multicenter, prospective study was conducted in Japan. A self-expandable metal stent with low axial force was inserted endoscopically. The primary endpoint was clinical success, defined as the resolution of symptoms and radiological findings within 24 h. Secondary endpoints were technical success and adverse events. Short-term outcomes of 7 days were evaluated in this study. (3) Results: Two hundred and five consecutive patients were enrolled. Three patients were excluded, and the remaining 202 patients were evaluated. The technical and clinical success rates were 97.5% and 96.0%, respectively. Major stent-related adverse events included stent migration (1.0%), insufficient stent expansion (0.5%), and stent occlusion (0.5%). No colonic perforation was observed. There were two fatal cases (1%) which were not related to stent placement. (4) Conclusions: The placement of self-expandable metal stents with low axial force is safe with no perforation and showed high technical and clinical success rates in short-term outcomes for the management of malignant colorectal obstruction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585095PMC
http://dx.doi.org/10.3390/jcm10214936DOI Listing

Publication Analysis

Top Keywords

self-expandable metal
16
short-term outcomes
12
low axial
12
axial force
12
malignant colorectal
12
colorectal obstruction
12
clinical success
12
colorectal stenting
8
metal stent
8
multicenter prospective
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!