Hypothesis: This study tests the hypothesis that it is possible to find tone or noise vocoders that sound similar and result in similar speech perception scores to a cochlear implant (CI). This would validate the use of such vocoders as acoustic models of CIs. We further hypothesize that those valid acoustic models will require a personalized amount of frequency mismatch between input filters and output tones or noise bands.
Background: Noise or tone vocoders have been used as acoustic models of CIs in hundreds of publications but have never been convincingly validated.
Methods: Acoustic models were evaluated by single-sided deaf CI users who compared what they heard with the CI in one ear to what they heard with the acoustic model in the other ear. We evaluated frequency-matched models (both all-channel and 6-channel models, both tone and noise vocoders) as well as self-selected models that included an individualized level of frequency mismatch.
Results: Self-selected acoustic models resulted in similar levels of speech perception and similar perceptual quality as the CI. These models also matched the CI in terms of perceived intelligibility, harshness, and pleasantness.
Conclusion: Valid acoustic models of CIs exist, but they are different from the models most widely used in the literature. Individual amounts of frequency mismatch may be required to optimize the validity of the model. This may be related to the basalward frequency mismatch experienced by postlingually deaf patients after cochlear implantation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8691967 | PMC |
http://dx.doi.org/10.1097/MAO.0000000000003373 | DOI Listing |
J Acoust Soc Am
December 2024
Key Laboratory of Underwater Acoustic Communication and Marine Information Technology of the Ministry of Education, College of Ocean and Earth Sciences, Xiamen University, Xiamen 361005, China.
Although air sinuses are prevalent in odontocetes and are an integral component of their sound reception system, the acoustic function of these air-filled structures remains largely unknown. To address this, we developed a numerical model using computed tomography data from a Yangtze finless porpoise (Neophocaena asiaeorientalis asiaeorientalis) to investigate the role of the air sinuses in sound reception. By comparing sound reception characteristics between model cases with and without the air sinuses, we found that the air sinuses improved sound reception directivity.
View Article and Find Full Text PDFMembranes (Basel)
December 2024
Laboratory of Physical-Chemistry, Department of Chemistry, Universidad Nacional del Sur (UNS), Bahía Blanca 8000, Argentina.
The present study investigates a multicomponent lipid system that simulates the neuronal grey matter membrane, employing molecular acoustics as a precise, straightforward, and cost-effective methodology. Given the significance of omega-3 polyunsaturated fatty acids in the functionality of cellular membranes, this research examines the effects of reducing 1-palmitoyl-2-docosahexaenoylphosphatylcholine (PDPC) content on the compressibility and elasticity of the proposed membrane under physiological conditions. Our results align with bibliographic data obtained through other techniques, showing that as the proportion of PDPC increases in the grey matter membrane model, the system's compressibility decreases, and the membrane's elasticity increases, as evidenced by the reduction in the bulk modulus.
View Article and Find Full Text PDFR Soc Open Sci
September 2024
Centre for Neuroscience in Education, University of Cambridge, Cambridge, UK.
French and German poetry are classically considered to utilize fundamentally different linguistic structures to create rhythmic regularity. Their metrical rhythm structures are considered poetically to be very different. However, the biophysical and neurophysiological constraints upon the speakers of these poems are highly similar.
View Article and Find Full Text PDFOrg Process Res Dev
December 2024
Materials Science Division, Lawrence Livermore National Laboratory, Livermore, California 94550, United States.
Control of powder properties is crucial for industrial processes across the food, pharmaceutical, agriculture, and mineral processing industries, and granulation is an important tool for providing agglomerated particles with controllable properties. However, existing granulation processes are not readily integrated with other processing steps and are not appropriate for some types of materials. Adding resonant acoustic-based granulation to the toolkit has the potential to widen the achievable parameter space and, importantly, integrate granulation into chemistry and blending operations that are already being performed on the RAM platform, resulting in process intensification.
View Article and Find Full Text PDFPhys Life Rev
December 2024
Center for Music in the Brain, Department of Clinical Medicine, Aarhus University and The Royal Academy of Music, Aarhus/Aalborg, Aarhus, Denmark; Department of Education, Psychology, Communication, University of Bari Aldo Moro, Italy. Electronic address:
In Western tonal music, major and minor modes are recognized as the primary musical features in eliciting emotional responses. The underlying correlates of this dichotomy in music perception have been extensively investigated through decades of psychological and neuroscientific research, yielding plentiful yet often discordant results that highlight the complexity and individual differences in how these modes are perceived. This variability suggests that a deeper understanding of major-minor mode perception in music is still needed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!