A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a point-of-care test for the detection of MDMA in latent fingerprints using surface plasmon resonance and lateral flow technology. | LitMetric

Development of a point-of-care test for the detection of MDMA in latent fingerprints using surface plasmon resonance and lateral flow technology.

Drug Test Anal

King's Forensics, Department of Analytical, Environmental & Forensic Sciences, Franklin-Wilkins Building, King's College London, 150 Stamford St, London, United Kingdom, SE1 9NH, UK.

Published: April 2022

To date, a specific point-of-care test (POCT) for 3,4-methylenedioxymethamphetamine (MDMA, ecstasy, 'E') in latent fingerprints (LFPs) has not been explored. Other POCTs identify MDMA in sweat by detecting the drug as a cross-reactant rather than target analyte, thus decreasing the test's sensitivity. The study's aim was to design a sensitive POCT for the detection of MDMA in LFPs using surface plasmon resonance (SPR) and lateral flow immunoassay (LFA) technology. A high-affinity antibody binding pair was identified using the former technique, deeming the pair suitable for a LFA. Titrations of fluorescently labelled antibody and antigen concentrations were tested to identify a sharp drop-in signal upon the addition of MDMA to allow a clear distinction between negative and positive outcomes. We trialled the LFA by producing dose response curves with MDMA and a group of drugs that share a similar chemical structure to MDMA. These were generated through spiking the LFA with increasing levels of drug (0-400 pg/10 μl of MDMA; 0-10,000 pg/10 μl of cross-reactant). Fluorescent test signals were measured using a cartridge reader. The cut-off (threshold) 60 pg/10 μl calculated better cartridge performance (1.00 sensitivity, 0.95 specificity and 0.98 accuracy), when compared with 40 pg/10 μl. The biggest cross-reactant was PMMA (250%), followed by MDEA (183%), MBDB (167%), MDA (16%) and methamphetamine (16%). A sensitive LFP screening tool requiring no sample preparation was successfully designed.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dta.3196DOI Listing

Publication Analysis

Top Keywords

point-of-care test
8
mdma
8
detection mdma
8
latent fingerprints
8
surface plasmon
8
plasmon resonance
8
lateral flow
8
development point-of-care
4
test detection
4
mdma latent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!