A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical and radiological outcomes of a stemless reverse shoulder implant: a two-year follow-up in 56 patients. | LitMetric

Clinical and radiological outcomes of a stemless reverse shoulder implant: a two-year follow-up in 56 patients.

JSES Int

Department for Shoulder and Elbow Surgery, St. Vinzenz-Klinik Pfronten, Pfronten, Germany.

Published: November 2021

Background: Since the introduction of stemless anatomic shoulder arthroplasty, many studies have been published on anatomic implants. For reverse stemless implants, however, there are only a few clinical follow-up studies available. The current clinical case series aims to present clinical and radiological outcomes of a new stemless reverse prosthesis system (Lima Shoulder Modular Replacement stemless).

Methods: We prospectively evaluated the outcome of 56 stemless total shoulder arthroplasties in 56 patients with a mean age of 61.2 years (46-76 years) at the time of implantation at a minimum follow-up of 24 months (range 24-41 months). All patients were physically and radiologically examined. Clinical outcomes were evaluated by using the Constant-Murley Score and the Subjective Shoulder Value.

Results: The mean Subjective Shoulder Value was 84.27% at the latest follow-up. Significant improvements from preoperative to latest follow-up were documented for Constant-Murley Score (34.9 pts to 74.43 pts,  < .001) and active range of motion (abduction 72° to 130°, flexion 36° to 138°, and external rotation 16°to 28°). There was one complete loosening of the humeral component without reoperation. Radiolucency lines were observed in anteroposterior or axial radiographs at the humeral component in 23% of the cases, most of them in anteroposterior view at the calcar region. Radiolucency line findings did not affect clinical outcomes. Major complications or revisions did not occur so far.

Conclusion: At short-term follow-up, stemless reverse shoulder systems show comparable clinical and radiological outcomes compared to stemmed reverse implants in the literature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8569012PMC
http://dx.doi.org/10.1016/j.jseint.2021.07.007DOI Listing

Publication Analysis

Top Keywords

clinical radiological
8
radiological outcomes
8
outcomes stemless
8
stemless reverse
8
constant-murley score
8
subjective shoulder
8
latest follow-up
8
shoulder
6
clinical
5
stemless
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!