Design and Testing of a Low-Cost Sensor and Sampling Platform for Indoor Air Quality.

Build Environ

Department of Mechanical Engineering, Colorado State University, 1374 Campus Delivery, Fort Collins, Colorado, United States 80523.

Published: December 2021

Americans spend most of their time indoors at home, but comprehensive characterization of in-home air pollution is limited by the cost and size of reference-quality monitors. We assembled small "Home Health Boxes" (HHBs) to measure indoor PM, PM, CO, CO, NO, and O concentrations using filter samplers and low-cost sensors. Nine HHBs were collocated with reference monitors in the kitchen of an occupied home in Fort Collins, Colorado, USA for 168 h while wildfire smoke impacted local air quality. When HHB data were interpreted using gas sensor manufacturers' calibrations, HHBs and reference monitors (a) categorized the level of each gaseous pollutant similarly (as either low, elevated, or high relative to air quality standards) and (b) both indicated that gas cooking burners were the dominant source of CO and NO pollution; however, HHB and reference O data were not correlated. When HHB gas sensor data were interpreted using linear mixed calibration models derived via collocation with reference monitors, root-mean-square error decreased for CO (from 408 to 58 ppm), CO (645 to 572 ppb), NO (22 to 14 ppb), and O (21 to 7 ppb); additionally, correlation between HHB and reference O data improved (Pearson's r increased from 0.02 to 0.75). Mean 168-h PM and PM concentrations derived from nine filter samples were 19.4 μg m (6.1% relative standard deviation [RSD]) and 40.1 μg m (7.6% RSD). The 168-h PM concentration was overestimated by PMS5003 sensors (median sensor/filter ratio = 1.7) and underestimated slightly by SPS30 sensors (median sensor/filter ratio = 0.91).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8577402PMC
http://dx.doi.org/10.1016/j.buildenv.2021.108398DOI Listing

Publication Analysis

Top Keywords

air quality
12
reference monitors
12
data interpreted
8
gas sensor
8
hhb reference
8
reference data
8
ppb ppb
8
sensors median
8
median sensor/filter
8
sensor/filter ratio
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!