Silicone-rubber baby teats used to bottle-feed infants are frequently disinfected by moist heating. However, infant exposure to small microplastics (<10 μm) potentially released from the heated teats by hydrothermal decomposition has not been studied, owing to the limitations of conventional spectroscopy in visualizing microplastic formation and in characterizing the particles at the submicrometre scale. Here both the surfaces of silicone teats subjected to steam disinfection and the wash waters of the steamed teats were analysed using optical-photothermal infrared microspectroscopy. This new technique revealed submicrometre-resolved steam etching on and chemical modification of the teat surface. Numerous flake- or oil-film-shaped micro(nano)plastics (MNPs) (in the size range of 0.6-332 μm) presented in the wash waters, including cyclic and branched polysiloxanes or polyimides, which were generated by the steam-induced degradation of the base polydimethylsiloxane elastomer and the polyamide resin additive. The results indicated that by the age of one year, a baby could ingest >0.66 million elastomer-derived micro-sized plastics (MPs) (roughly 81% in 1.5-10 μm). Global MP emission from teat disinfection may be as high as 5.2 × 10 particles per year. Our findings highlight an entry route for surface-active silicone-rubber-derived MNPs into both the human body and the environment. The health and environmental risks of the particles are as yet unknown.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41565-021-00998-x | DOI Listing |
Int Ophthalmol
November 2024
Department of Ophthalmology, Cullen Eye Institute, Baylor College of Medicine, Houston, TX, USA.
Purpose: To determine the pre-operative, peri-operative, or post-operative risk factors that contribute to pediatric frontalis sling infection or exposure.
Methods: Retrospective study of 193 eyelids that underwent silicone-rod frontalis sling surgery at a single institution between 2014 and 2019.
Results: A total of 222 eyelids were originally identified.
J Biomed Opt
May 2024
Florida International University, Department of Biomedical Engineering, Miami, Florida, United States.
J Environ Sci (China)
February 2024
State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China. Electronic address:
Nano-enabled silicone-rubber articles for feeding or chewing could be a source of metallic nanoparticles (NPs) directly exposed to infants and young children. However, the impact of steam disinfection on release of NPs and the related potential risks to children's health are unknown. Here, we investigated contents and form of Ag and Zn in 57 nano-enabled silicone-rubber baby bottle teats, pacifiers, and teethers of seven countries and examined the impacts of steam disinfection on in vitro bioaccessibility (IVBA) of Ag and Zn in the articles.
View Article and Find Full Text PDFCan J Ophthalmol
August 2024
Division of Ophthalmology, Children's Hospital of Philadelphia and the Edwin and Fannie Gray Hall Center for Human Appearance, University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA.
Objective: To compare the outcome of silicone sling frontalis suspension (FS) surgery in children with simple congenital ptosis and children with complex ptosis.
Design: A retrospective cohort study.
Participants: All pediatric patients who underwent silicone sling FS surgery between 2009 and 2020 at a single centre.
Congenit Anom (Kyoto)
January 2023
Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Ohu University School of Dentistry, Koriyama City, Fukushima, Japan.
Patients with cleft lip and palate (CLP) encounter various problems, including disorders related to feeding, esthetics, and pronunciation. We compared two impression methods, conventional impression making and intraoral scanning, to study unilateral cleft lip and palate (UCLP). Patients with UCLP (n = 7) were selected, and palatal impressions were taken by two steps: (1) impressions were obtained using an addition silicone rubber impression material, and a plaster model was prepared and (2) optical impressions were obtained using a desktop three-dimensional (3D) scanner and stereolithography (STL).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!