AI Article Synopsis

  • AI can indirectly assess aortic dilation from CT images, which relates to blood pressure, potentially aiding in diagnosing conditions like masked hypertension.
  • The study involved 801 patients and used AI-Rad Companion to automatically measure aortic diameter at specific locations, validated by regulatory bodies like the FDA.
  • Results indicated that aortic diameter is a significant risk factor for adverse blood pressure conditions, with the mid descending aorta position being the most effective for hypertension identification and screening.

Article Abstract

Introduction And Objectives: Artificial intelligence (AI) made it achievable that aortic dilation could be measured in CT images indirectly, while aortic diameter (AD) has the certain relationship with blood pressure. It was potential that the blood pressure condition be determined by AD measurement using the data obtained from a CT scanning especially in identifying masked hypertension and predicting the risk of poor control of blood pressure (BP) which was easy to elude diagnosis in clinic. We aimed to evaluate the possibility of utilizing AD by AI for predicting the risk of adverse BP status (including masked hypertension or poor BP control) and the optimal thoracic aortic position in measurement as well as the cutoff value for predicting the risk.

Methods: Eight hundred and one patients were enrolled in our study. AI-Rad Companion Cardiovascular (K183268 FDA approved) was used to perform automatic aorta measurement in thoracic CT images at nine key positions based on AHA guidelines. Data was post processed by software from AI-Rad Companion undergone rigorous clinical validation by both FDA and CE as verification of its efficacy and usability. The AD's risk and diagnostic value was assessed in identifying hypertension in the general population, in identifying the poor BP controlled in the hypertension population, and in screening masked hypertension in the general population respectively by multiple regression analysis and receiver operating curve analysis.

Results: AD measured by AI was a risk factor for adverse BP status after clinical covariates adjustment (OR = 1.02 ~ 1.26). The AD at mid descending aorta was mostly affected by BP particularly, which is optimal indicator in identifying hypertension in the general population (AUC = 0.73) and for screening masked hypertension (AUC = 0.78).

Conclusion: Using AI to measure the AD of the aorta, particularly at the position of mid descending aorta, is greatly valuable for identifying people with poor BP status. It will be possible to reveal more clinical information reflected by ordinary CT images and enrich the screening methods for hypertension, especially masked hypertension.HTN has a significant adverse effect on arterial deformation. BP and arterial dilation promote each other in a vicious circle. Arterial dilation may not be restricted by apparent fluctuations in BP and is objective evidence of an undesirable BP state. The accuracy of AD measurements by AI on chest CT images has been verified. There has not been the application of AD measurement by AI in the scene of poor BP status in clinical practice.In this study, we applied AI to measure the diameter of the aorta in nine consecutive positions. We explored the association between AD at various positions and BP levels and the possibility that AD in identifying poor BP status in different populations. We found that the AD at the MD is of great value in screening MH and evaluating the control state of BP in HTN. It will be possible to significantly expand the clinical information reflected by ordinary CT images and enrich the screening methods for HTN, especially MH.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00325481.2021.2003150DOI Listing

Publication Analysis

Top Keywords

masked hypertension
20
blood pressure
16
hypertension general
12
general population
12
poor status
12
hypertension
9
artificial intelligence
8
aortic diameter
8
status including
8
including masked
8

Similar Publications

Prcis: Preservative-free omidenepag isopropyl (OMDI) 0.002% ophthalmic solution and OMDI 0.002% ophthalmic solution preserved with benzalkonium chloride were bioequivalent in lowering intraocular pressure after 4 weeks' treatment in patients with primary open-angle glaucoma or ocular hypertension.

View Article and Find Full Text PDF

Background: Patients with solitary functioning kidney appear to be exposed to an increased cardiovascular risk. This study aimed to evaluate the impact of peripheral and central blood pressure on subclinical cardiovascular organ damage in a sample of children and adolescents with solitary functioning kidney.

Methods: Carotid ultrasonography was performed to measure the carotid intima-media thickness (cIMT) and the carotid distensibility coefficient.

View Article and Find Full Text PDF

Background: Hypertension is a leading cause of premature mortality and morbidity. Recent guidelines advocate for out-of-office blood pressure monitoring, including ambulatory and home BP monitoring, to better identify hypertension phenotypes like masked hypertension, white coat hypertension, and sustained hypertension. However, clinical inertia persists due to a lack of robust evidence on the effectiveness of screening these phenotypes and their association with cardiovascular and all-cause mortality.

View Article and Find Full Text PDF

Background: Out-of-office blood pressure (BP) measurement devices, such as ambulatory BP monitoring (ABPM) and home BP monitoring (HBPM), enhance the accuracy and reliability of BP readings, detecting white-coat and masked hypertension. The American Heart Association (AHA) advises confirming hypertension diagnoses with ABPM to prevent overdiagnosis, emphasizing the importance of precise out-of-office diagnostic tools. This study aimed to 1) explore the prevalence of ABPM and HBPM use prior to hypertension diagnosis; 2) assess the adherence to AHA recommendations regarding ABPM utilization; and 3) investigate the association between patient characteristics and out-of-office BP monitoring practices.

View Article and Find Full Text PDF

Aim: The prognosis of masked hypertension is controversial. The aims of this meta-analysis were to determine the global prevalence of masked hypertension and to better understand its association with the risk of cardiorenal comorbidities and all-cause mortality.

Methods: We searched the PubMed, Embase (OVID), The Cochrane Library, WanFang Data, and CNKI databases for relevant studies published from inception until January 15, 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!