A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative effect of dense-and-disperse versus non-repetitive and non-sequential frequencies in electroacupuncture-induced analgesia in a rodent model of peripheral neuropathic pain. | LitMetric

Background: Neuropathic pain (NP) is a complex disease that remains challenging to treat. Low-frequency dense-and-disperse (DD) electroacupuncture (EA) has been used as adjuvant therapy for neuropathic pain; however, its analgesic effect decreases as stimulation time increases, or when it is repeatedly used. We hypothesized that a new frequency parameter could improve the effectiveness of EA, and aimed to compare the efficacy and duration of the analgesic effect between classic DD-EA and non-repetitive and non-sequential frequency (random frequency (RF)-EA) in neuropathic rats. Furthermore, the effect of RF-EA at local traditional acupuncture point locations versus auricular vagus nerve stimulation (aVNS) was evaluated.

Methods: Male Wistar rats with peripheral neuropathy were subjected to a single session of DD-EA or RF-EA for 20 or 40 min at ST36 + GB34. An additional group of rats was treated with RF-EA for 20 min using aVNS at the appropriate ear point locations. Paw pressure test, von Frey filaments and spontaneous pain scores were evaluated. Sham-operated rats were used as controls.

Results: In all, 20 min of RF-EA reversed hyperalgesia (for 24 h) and allodynia (for 8 h), showing a longer analgesic effect than DD-EA. Both RF-EA and DD-EA induced partial inhibition of spontaneous pain for 8 h. Forty minutes of DD-EA did not interfere with the NP phenomena; however, RF-EA induced significant long-term analgesia. aVNS induced an analgesic effect similar to local stimulation.

Conclusion: This pilot study shows that RF-EA at both local traditional acupuncture point and auriculotherapy point locations induces long-lasting analgesia in neuropathic rats, and more effectively so than classical DD-EA.

Download full-text PDF

Source
http://dx.doi.org/10.1177/09645284211055751DOI Listing

Publication Analysis

Top Keywords

neuropathic pain
12
point locations
12
non-repetitive non-sequential
8
rf-ea
8
neuropathic rats
8
rf-ea local
8
local traditional
8
traditional acupuncture
8
acupuncture point
8
dd-ea rf-ea
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!