Non-destructive determination of functionalized polyelectrolyte placement in layer-by-layer films by IR ellipsometry.

Soft Matter

Department of Chemical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.

Published: December 2021

AI Article Synopsis

  • Layer-by-layer (LbL) assembly allows tailored coatings on various surfaces by choosing specific material pairs, but traditional characterization methods can be destructive and require large compositional differences.
  • A new non-destructive method using infrared (IR) spectroscopic ellipsometry measures the depth of allyl content in films made of poly(diallyldimethylammonium chloride) (PDAC) and poly(sodium acrylate--allylacrylamide) (allyl-PAA).
  • Results show that this method can track the growth patterns and gradients in these films during the LbL process, providing insight into the mechanisms driving the exponential growth observed in LbL assemblies.

Article Abstract

Layer-by-layer (LbL) assembly facilitates controlled coatings on a variety of surfaces with the ability to manipulate the composition through the thickness by selection of the complementary pairs. However, the characterization of these composition profiles tends to be destructive and requires significant compositional differences that can limit their utility. Here, we demonstrate the ability to non-destructively quantify the depth dependence of the allyl content associated with the selective incorporation of poly(sodium acrylate--allylacrylamide) (84 : 16 mol : mol) (allyl-PAA) in LbL films based on the assembly of poly(diallyldimethylammonium chloride) (PDAC)/poly(acrylic acid) (PAA) and PDAC/allyl-PAA. Although the atomic composition of the film is not dramatically influenced by the change between PAA and allyl-PAA, the absorption in the IR near 1645 cm by the allyl group provides sufficient optical contrast to distinguish the LbL components with spectroscopic ellipsometry. The use of IR spectroscopic ellipsometry can determine the thickness of layers that contain allyl-PAA and also gradients that develop due to re-arrangements during the LbL process. With multiple films fabricated simultaneously, the location of the gradient between the 1st and 2nd series of multilayers (, first PDAC/PAA bilayers and then PDAC/allyl-PAA bilayers) can be readily assessed. The results from a variety of different multilayer architectures indicate that the gradient is located within the thickness expected for the 1st deposited bilayer stack (PDAC/PAA or PDAC/allyl-PAA). These results are indicative of a dynamic dissolution-deposition process (in- and out- diffusion) during the fabrication of these LbL films. These results provide additional evidence into the mechanisms for exponential growth in LbL assemblies. The ability to quantify a gradient with the low contrast system examined indicates that spectroscopic IR ellipsometry should be able to non-destructively determine compositional gradients for most polymer films where such gradients exist.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1sm01246kDOI Listing

Publication Analysis

Top Keywords

spectroscopic ellipsometry
12
lbl films
8
lbl
6
films
5
non-destructive determination
4
determination functionalized
4
functionalized polyelectrolyte
4
polyelectrolyte placement
4
placement layer-by-layer
4
layer-by-layer films
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!