An origami paper-based peptide nucleic acid device coupled with label-free DNAzyme probe hybridization chain reaction for prostate cancer molecular screening test.

Anal Chim Acta

Biosensors and Bioanalytical Technology for Cell and Innovative Testing Research Unit, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand. Electronic address:

Published: November 2021

Prostate cancer associated 3 (PCA3) assay has been used to improve prostate cancer diagnosis and reduce unnecessary biopsies. In this work, we successfully developed a new PCA3 assay on an origami paper-based peptide nucleic acid device (oPAD). The PCA3 oPAD comprises an acrylic cassette and shutter slides to facilitate the molecular reaction and liquid control occurring on the paper surface. To quantify PCA3, a pyrrolidinyl peptide nucleic acid (acpcPNA) was immobilized onto the aldehyde-modified oPAD surface as a selective capture probe. A G-quadruplex (GQD) DNAzyme reporter probe was designed so that the PCA3 gene target binding triggered the hybridization chain reaction of the reporter probe, resulting in the accumulation of the GQD on the oPAD. The peroxidase activity of the GQD-hemin generated a deep green color of the oxidized ABTS substrate. Image analyses were performed in Adobe Photoshop CS6. The proposed oPAD was successfully applied in PCA3 detection ranges of 1-5 μM (r = 0.982) with a limit of detection of 0.5 μM. Our proposed oPAD was demonstrated to measure PCA3 samples in both urine matrix and human cancer cell lines. The results reveal the great potential of our origami paper-based platform to be an alternative approach for facile, rapid, and low-cost detection of PCA3 in real samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2021.339130DOI Listing

Publication Analysis

Top Keywords

origami paper-based
12
peptide nucleic
12
nucleic acid
12
prostate cancer
12
paper-based peptide
8
acid device
8
hybridization chain
8
chain reaction
8
pca3
8
pca3 assay
8

Similar Publications

Novel and simple spectrophotometric and distance based procedures for thiols (L-cysteine, N-acetylcysteine, and glutathione) determination in biological fluids and pharmaceuticals have been proposed based on their inhibitory action on the oxidation of catechol in the presence of Agaricus bisporus crude extract (ABE). The influence of L-glycine, L-alanine, L-proline, L-methionine, L-cystine, ascorbic acid, uric acid, and bilirubin on the thiol determination has been investigated. Uric acid, bilirubin, L-cystine (oxidized thiol), and L-amino acids do not interfere with the determination.

View Article and Find Full Text PDF

Eco-sustainable point-of-care devices: Progress in paper and fabric based electrochemical and colorimetric biosensors.

Talanta

December 2024

Department of Sensor and Biomedical Technology, School of Electronics Engineering (SENSE), Vellore Institute of Technology, Vellore, 632014, India. Electronic address:

Monitoring real-time health conditions is a rinsing demand in a pandemic prone era. Wearable Point-of-Care (POC) devices with paper and fabric-based sensors are emerging as simple, low-cost, portable, and disposable analytical tools for development of green POC devices (GPOCDs). Capabilities of passive fluid transportation, compatibility with biochemical analytes, disposability and high degree of tunability using vivid device fabrication strategies enables development of highly sensitive and economically feasible POC sensors in particularly post COVID-19 pandemic outbreak.

View Article and Find Full Text PDF

YoMo: Yoshimura Continuum Manipulator for MR Environment.

Soft Robot

October 2024

College of Artificial Intelligence, Nankai University, Tianjin, China.

Origami robots have garnered attention due to their versatile deformation and potential applications, particularly for medical applications. In this article, we propose a Yoshimura continuum manipulator (YoMo) that can achieve accurate control of the tip position for the magnetic resonance (MR) environment. The YoMo made of a single piece of paper is cable-actuated to generate the bending and shortening deformation.

View Article and Find Full Text PDF

3D Paper-Based Device Integrated with a Battery-Less NFC Potentiostat for Nonenzymatic Detection of Cholesterol.

ACS Meas Sci Au

August 2024

Sensor Technologist, Silicon Craft Technology Public Company Limited, Bangkok 10900, Thailand.

Portable electrochemical analytical devices such as cholesterol sensors are widely used for disease diagnosis. However, these tools are bulky and require bioreceptors for the specific detection of cholesterol. Herein, a novel 3D electrochemical paper-based analytical device (3D-ePAD) combined with a near-field communication (NFC) potentiostat was developed and applied to the nonenzymatic detection of cholesterol.

View Article and Find Full Text PDF

Stretchable Triboelectric Nanogenerator Based on Liquid Metal with Varying Phases.

Adv Sci (Weinh)

October 2024

Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, 16802, USA.

Stretchable triboelectric nanogenerators (TENGs) represent a new class of energy-harvesting devices for powering wearable devices. However, most of them are associated with poor stretchability, low stability, and limited substrate material choices. This work presents the design and demonstration of highly stretchable and stable TENGs based on liquid metalel ectrodes with different phases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!