Background: Transpedicular screws are extensively utilized in lumbar spine surgery. The placement of these screws is typically guided by anatomical landmarks and intraoperative fluoroscopy. Here, we utilized 2-week postoperative computed tomography (CT) studies to confirm the accuracy/inaccuracy of lumbar pedicle screw placement in 145 patients and correlated these findings with clinical outcomes.
Methods: Over 6 months, we prospectively evaluated the location of 612 pedicle screws placed in 145 patients undergoing instrumented lumbar fusions addressing diverse pathology with instability. Routine anteroposterior and lateral plain radiographs were obtained 48 h after the surgery, while CT scans were obtained at 2 postoperative weeks (i.e., ideally these should have been performed intraoperatively or within 24-48 h of surgery).
Results: Of the 612 screws, minor misplacement of screws (≤2 mm) was seen in 104 patients, moderate misplacement in 34 patients (2-4 mm), and severe misplacement in 7 patients (>4 mm). Notably, all the latter 7 (4.8% of the 145) patients required repeated operative intervention.
Conclusion: Transpedicular screw insertion in the lumbar spine carries the risks of pedicle medial/lateral violation that is best confirmed on CT rather than X-rays/fluoroscopy alone. Here, we additional found 7 patients (4.8%) who with severe medial/lateral pedicle breach who warranting repeated operative intervention. In the future, CT studies should be performed intraoperatively or within 24-48 h of surgery to confirm the location of pedicle screws and rule in our out medial or lateral pedicle breaches.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8571410 | PMC |
http://dx.doi.org/10.25259/SNI_290_2021 | DOI Listing |
Arch Orthop Trauma Surg
December 2024
Sitaram Bhartia Institute of Science and Research, New Delhi, India.
Purpose: Achieving precise postoperative alignment is critical for the long-term success of total knee arthroplasty (TKA). Long-leg standing radiograph (LLR) at 6 weeks post-op is the gold standard for assessing alignment, but its reliance on weight-bearing and positioning makes it less practical in the early postoperative period. Supine computed tomography scanogram (CTS) offers a potential alternative.
View Article and Find Full Text PDFBMC Cardiovasc Disord
December 2024
School of Psychology, University of Southampton, Southampton, UK.
Background: Blood pressure (BP) control following stroke is important but currently sub-optimal. This trial aimed to determine whether self-monitoring of hypertension with telemonitoring and a treatment escalation protocol, results in lower BP than usual care in people with previous stroke or transient ischaemic attack (TIA).
Methods: Unblinded randomised controlled trial, comparing a BP telemonitoring-based intervention with control (usual care) for hypertension management in 12 primary care practices in England.
Sci Rep
December 2024
Department of Urology, Gongli Hospital of Shanghai Pudong New Area, 219 Miao Pu Road, Shanghai, 200135, China.
To report the procedure of an alternative modified transvaginal repair technique (V-NOTES) and their outcomes in apical vesicovaginal fistula. Between January 2020 and January 2023, gynecological procedures resulted in the diagnosis of apical VVFs in 26 patients, 17 of whom had undergone transvaginal repair of apical vesicovaginal fistula via vaginal V-NOTES. Those patients were contacted and followed up.
View Article and Find Full Text PDFInt J Med Inform
December 2024
Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania "Luigi Vanvitelli", Naples, Italy. Electronic address:
Background: Usefulness of hysteroscopic metroplasty to improve reproductive outcomes is controversial and debated among reproductive specialists and, consequently, patients.
Methods: We performed a cross-sectional analysis to assess the quality, reliability, and level of misinformation in YouTube, Instagram, and TikTok videos about hysteroscopic metroplasty. Videos on each social network retrieved using "hysteroscopy" and "septate uterus" or "uterine septum" as keywords were assessed using Patient Education Materials Assessment Tool for audio-visual (PEMAT A/V) content, the modified DISCERN (mDISCERN), Global Quality Scale (GQS), Video Information and Quality Index (VIQI) and Misinformation assessment.
J Neurosurg Spine
December 2024
1Department of Orthopaedic Surgery, The Och Spine Hospital/Columbia University Irving Medical Center, New York, New York.
Objective: The objective of this study was to compare a multiple pelvic screw fixation strategy (dual bilateral 4 pelvic screw fixation [4PvS]) with the use of single bilateral 2 pelvic screw fixation (2PvS), with the aim of addressing lumbosacral junction stability.
Methods: This analysis is a single-center, retrospective review of ASD patients treated between 2015 and 2021. All patients had a minimum 2-year follow-up and spinal fusion to the sacrum without sacroiliac fusion and met at least one radiographic and procedural criterion: pelvic incidence-lumbar lordosis ≥ 20°, T1 pelvic angle ≥ 20°, sagittal vertical axis ≥ 7.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!