Background And Objectives: The left atrial appendage (LAA) is the most common region for thrombus formation in atrial fibrillation (AF). Morphological parameters such as shape, size, and LAA volume can cause insufficient effectiveness of available therapeutic options. This study aimed to examine blood flow inside LAA and its removal effects. Computational fluid dynamic (CFD) simulations were carried out on two patients with different morphologies.

Methods: Two patients' CT was used to reconstruct the 3D geometries of the left atrium (LA) and left atrial appendage (LAA). Then, the geometries were refined in the mentioned software, and the LAA in some models was removed. Next, in generated 3D volume mesh, sinus rhythm (SR) and atrial fibrillation (AF) outflow velocity were imposed at the mitral valve as boundary conditions. Finally, CFD simulation was conducted to analyzing blood flow within LA with/without LA.

Results: The results confirmed that velocity and vorticity decreased under AF conditions inside the LA domain for both patients. However, removing LAA may cause unpredictable consequences, due to different shape and volume of LAA. LAA removal had insignificant effects on velocity and vorticity within LA in SR-mitral outflow. However, removing LAA increased the blood flow rate by 9.15% and vorticity by 7.27% for patient one under AF rhythm (SR)-outflow. In contrast, for patient two, LAA removal in both AF and SR decreased velocity and vorticity within the LA domain. In SR-mitral outflow, velocity dropped by 18.8 %, and vorticity by 13.2%. Also, under AF velocity and vorticity decreased by 23.33% and 18.6% respectively. Meanwhile, the results indicated that the vorticity magnitude increased inside the LAA under AF associated with the risk of thrombus formation, particularly for patient one under AF. The distal part of LAA in both patients was the most common region for blood stasis because of the lowest velocity magnitude.

Conclusion: Overall, the morphology of LAA could be the critical parameter to determine the possibility of thrombosis formation, particularly under AF conditions. High volume, low blood flow velocity and two-lobe-appendage are more likely to have blood stasis. Furthermore, the morphology difference can affect the LAA removal result and make it more complicated. So, it could be challenging to generalize LAA removal as a therapeutic option for different patients. The implication of this CFD observation needs more investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2021.106506DOI Listing

Publication Analysis

Top Keywords

laa removal
20
left atrial
16
blood flow
16
velocity vorticity
16
laa
15
atrial appendage
12
appendage laa
8
common region
8
thrombus formation
8
atrial fibrillation
8

Similar Publications

Background: Left ventricular unloading is needed in patients on extracorporeal life support (ECLS) with severely impaired left ventricular contractility to avoid stasis and pulmonary congestion, and to promote LV recovery. The presence of thrombi in the LV precludes the use of conventional active unloading methods such as transaortic microaxial pumps or apical LV vents. We describe placement of a vent cannula via the left atrial appendage (LAA) as a useful bailout option.

View Article and Find Full Text PDF

Aims: The left atrial appendage (LAA) produces natriuretic peptides and its removal or occlusion might increase the risk of heart failure (HF). We aimed to investigate the incidence of HF after LAA occlusion or removal (LAAO) in the Left Atrial Appendage Occlusion Study (LAAOS III).

Methods And Results: Patients (n = 4811) with atrial fibrillation (AF) and a CHADS-VASc score ≥2, who were having cardiac surgery for another indication, were randomized to undergo surgical LAAO or not.

View Article and Find Full Text PDF
Article Synopsis
  • Left atrial appendage (LAA) occluder embolization is a rare but critical complication occurring mostly within the first 24 hours after the procedure, with data collected from 67 centers on 108 patients.
  • The management strategies included attempting percutaneous retrieval in 75% of cases, while 21.3% of patients underwent surgery without prior attempts, highlighting significant mortality rates associated with multiple retrieval attempts.
  • Overall, a major adverse event rate of 43.5% was observed, underscoring the serious risks, including death, particularly following unsuccessful retrievals.
View Article and Find Full Text PDF

Background: Left atrial appendage closure (LAAC) is a treatment modality for stroke prevention in patients with atrial fibrillation (AF). One of the potential complications of LAAC is a peri-device leak (PDL), which could potentially increase the risk of thromboembolism formation.

Methods: This systematic review was done according to PRISMA guidelines.

View Article and Find Full Text PDF

Background: Closure of the left atrial appendage (LAA) using a clip in at-risk patients reduces stroke risk. The rate of LAA closure procedures is increasing worldwide; however, complications have been reported, with coronary compression being one possible lethal complication associated with the anatomical structures around the LAA.

Case Summary: A 75-year-old man presented with a diagnosis of a φ50 mm saccular thoracic aortic aneurysm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!