Atrioventricular nodal reentrant tachycardia (AVNRT) is a common supraventricular tachycardia. Current guidelines recommend electrophysiology study (EPS) and ablation, which have been proven to show high success rates with very low complication rates. Usually, ablation of AVNRT is performed conventionally using only fluoroscopy. Electroanatomical mapping systems (EMS) are widely used in complex arrhythmias. One of their advantages is their potential in decreasing the need of fluoroscopy time (FT). In this study we analyzed patients undergoing either conventional AVNRT ablation or by using an EMS with a fluoroscopy integrating system (FIS). We included 119 patients who underwent AVNRT ablation in our study. Eighty-nine patients were ablated conventionally using only fluoroscopy, 30 patients were ablated using EMS + FIS. We found that the use of EMS + FIS led to a significant reduction of FT (449.90 ± 217.21 vs. 136.93 ± 109.28 sec., < 0.001) and dose-area-product (DAP, 268.27 ± 265.20 vs. 41.07 ± 27.89 μGym, < 0.001) without affecting the procedure time (PT, 66.55 ± 13.3 vs. 67.33 ± 13.81 min, = 0.783). Furthermore, we found no significance with regard to complications. The use of EMS+FIS is safe and feasible. It leads to a significant reduction of both FT and DAP without affecting PT and safety. Hence, EMS + FIS is beneficial for both the operator and the patients by reducing the radiation exposure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8563834 | PMC |
http://dx.doi.org/10.3389/fcvm.2021.728422 | DOI Listing |
Naunyn Schmiedebergs Arch Pharmacol
October 2023
Department of Breast Cancer Surgery, Harbin Medical University Cancer Hospital, Harbin Medical University, Haping RD NO, 150086, Harbin, Heilongjiang Province, People's Republic of China.
Sci Rep
May 2022
Atmosphere and Ocean Research Institute, The University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa, Chiba, 277-8568, Japan.
Between the Last Glacial Maximum and the mid-Holocene, the Mediterranean Sea experienced major hydrological changes. The deposition of the last sapropel, S1, during the Early Holocene is a consequence of these changes. In order to cause anoxia in the Eastern Mediterranean Sea (EMS) bottom water, a long preconditioning period of a few thousand years would need to occur throughout the deglaciation prior to S1.
View Article and Find Full Text PDFNanomaterials (Basel)
May 2022
Physics Center of Minho and Porto Universities (CF-UM-UP), Campus de Azurém, University of Minho, 4800-058 Guimarães, Portugal.
Optical biosensors based on localized surface plasmon resonance (LSPR) are the future of label-free detection methods. This work reports the development of plasmonic thin films, containing Au nanoparticles dispersed in a TiO matrix, as platforms for LSPR biosensors. Post-deposition treatments were employed, namely annealing at 400 °C, to develop an LSPR band, and Ar plasma, to improve the sensitivity of the Au-TiO thin film.
View Article and Find Full Text PDFPolymers (Basel)
November 2021
BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain.
This work reports on the production of poly(vinylidene fluoride) (PVDF) membranes by non-solvent induced phase separation (NIPS) using ,-dimethylformamide (DMF) as solvent and water as non-solvent. The influence of the processing conditions in the morphology, surface characteristics, structure, thermal and mechanical properties were evaluated for polymer dissolution temperatures between 25 and 150 °C and conditioning time between 0 and 10 min. Finger-like pore morphology was obtained for all membranes and increasing the polymer dissolution temperature led to an increase in the average pore size (≈0.
View Article and Find Full Text PDFFront Cardiovasc Med
October 2021
Department of Cardiology, Heart Centre Niederrhein, Helios Clinic Krefeld, Krefeld, Germany.
Atrioventricular nodal reentrant tachycardia (AVNRT) is a common supraventricular tachycardia. Current guidelines recommend electrophysiology study (EPS) and ablation, which have been proven to show high success rates with very low complication rates. Usually, ablation of AVNRT is performed conventionally using only fluoroscopy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!