  • Researchers implanted advanced rate-adaptive pacemakers with accelerometer and remote monitoring in miniature donkeys suffering from severe heart block and fainting episodes.
  • The testing of different programming modes showed that the pacemaker's closed loop stimulation (CLS) effectively adjusted pacing rates in response to the donkeys' heart activity, mimicking normal physiological responses.
  • The remote monitoring feature enabled daily wireless data transmission to a secure server, facilitating continuous oversight of the donkeys' heart health and prompt detection of any issues from afar.

Article Abstract

Rate-adaptive single chamber pacemakers with accelerometer, closed loop stimulation (CLS), and remote monitoring functionality (Eluna 8 SR-T, Biotronik, SE & Co, Germany) were implanted in 3 miniature donkeys with third-degree atrioventricular block and syncope. After recovery, different pacemaker programming modes were tested at rest, during stress without physical exercise and during physical exercise. Pacing rates were compared to actual atrial rates and showed that CLS functionality allowed physiological heart rate adaptation. A transmitter installed in the stable provided wireless connection of the pacemaker to the internet. Home monitoring was activated which performed daily wireless transmission of pacemaker functional measurements to an online server allowing diagnosis of pathological arrhythmias and pacemaker malfunction from a distance. Closed loop stimulation and remote monitoring functionality resulted in nearly physiological rate adaptation and allowed remote "from-the-stable" patient follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8692216PMC
http://dx.doi.org/10.1111/jvim.16305DOI Listing

Publication Analysis

Top Keywords

closed loop
12
loop stimulation
12
remote monitoring
12
miniature donkeys
8
monitoring functionality
8
physical exercise
8
rate adaptation
8
successful application
4
application closed
4
stimulation pacemakers
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!