The use of sutureless securement devices during catheterization might reduce the risk of catheter-related bloodstream infection (CRBSI) by suppressing catheter-exit infection and catheter dislodgement. However, the effectiveness of these devices in reducing CRBSI risk when securing hemodialysis catheters has not been explored. This single-center retrospective observational study examined 211 non-tunneled hemodialysis catheters (NTHCs) from 110 hemodialysis inpatients, of which 121 were secured using conventional skin sutures (Suture group) and 90 with GRIP-LOK (GRIP-LOK group). The stabilized inverse probability of treatment (SIPT)-weighting method was used to generate a new population (SIPT-weighted model) without group differences for each of the 12 predictors of CRBSI development (i.e., age, sex, dialysis history, concomitant acute kidney injury or diabetes, concurrent use of immunosuppressant drugs or aspirin, NTHC insertion site, methicillin-resistant Staphylococcus aureus, carriage, bacteremia event within 3 months before catheterization, hemoglobin level, and serum albumin titer). The effect of GRIP-LOK compared with sutures on CRBSI in the SIPT-weighted model was evaluated using univariate SIPT-weighted Cox proportional regression analysis, which showed a significant CRBSI suppression effect of GRIP-LOK compared with sutures (hazard ratio: 0.17 [95% CI 0.04-0.78], p = 0.023). GRIP-LOK affords a lower risk of CRBSI due to indwelling NTHCs than conventional securement using sutures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8571352 | PMC |
http://dx.doi.org/10.1038/s41598-021-01372-6 | DOI Listing |
Cureus
December 2024
Department of Ophthalmology, Shimane University Faculty of Medicine, Izumo, JPN.
We report three cases demonstrating the efficacy and versatility of the micro-incision scleral tunnel (MIST) technique, a novel method for Ahmed glaucoma valve (AGV) tube insertion. MIST is characterized by its small incision, sutureless approach, anterior-to-posterior tunnel creation, and allograft-free design. The technique involves creating a scleral tunnel using a 1-mm crescent knife (Bleb Knife II), allowing for secure tube placement into the anterior chamber, ciliary sulcus, or vitreous cavity.
View Article and Find Full Text PDFAdv Mater
November 2024
Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea.
Plast Reconstr Surg Glob Open
September 2024
Peripheral Nerve Surgery Department, Queen Elizabeth Hospital Birmingham, Birmingham, United Kingdom.
Background: Microsuturing, the gold standard for peripheral nerve repair, can create tension and damage at the repair site, potentially impacting regeneration and causing neuroma formation. A sutureless and atraumatic polymer-assisted system was developed to address this challenge and support peripheral nerve repair. The system is based on a biocompatible and biodegradable biosynthetic polymer and consists of a coaptation chamber and a light-activated polymer for securing to the nerve.
View Article and Find Full Text PDFNurs Rep
August 2024
Direction of Health and Social Professions, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy.
JAMA Pediatr
September 2024
Children's Health Queensland Hospital and Health Service, Brisbane, Australia.
Importance: Catheter dislodgement is a common complication for children with tunneled or peripherally inserted noncuffed central venous catheters (CVCs). A subcutaneous anchor securement system (SASS) may reduce this risk compared with traditional adhesive securement.
Objective: To compare dislodgement of noncuffed CVCs secured with SASS with dislodgement of noncuffed CVCs secured with sutureless securement devices (SSDs).