Background: The microbiological implications of septic failure after 1-stage exchange for prosthetic joint infection (PJI) of the hip remain unclear.
Methods: Information was gathered on comorbidities, previous procedures, preoperative and postoperative microbiology results, methods of detection, and antibiotic resistance patterns, for all patients, who developed septic failure after 1-stage exchange for PJI of the hip performed at our institution during 2001-2017.
Results: Seventy-seven patients were identified. Septic failure was diagnosed a mean of 1.7 (standard deviation 2.3, range 0-11.8) years later. Although the spectrum of microorganisms was similar to preoperative, in the majority of patients (55%), the initial microorganism(s) was (were) replaced by (a) totally different microorganism(s). Overall, there was a decrease in the number of polymicrobial PJIs. The number of patients with high virulent microorganisms decreased significantly from 52 to 36 (P = .034). The number of PJIs due to gram-negative pathogens remained similar (11 vs 14, P = .491). The number of rifampicin-resistant staphylococci, fluoroquinolone-resistant streptococci, enterococci, and fungi changed from 8 to 15, 0 to 2, 7 to 3, and 1 to 2, respectively, but these changes did not reach statistical significance.
Conclusion: The majority of reinfections is caused by different infecting bacteria, hence it is essential to perform a new diagnostic workup and not base treatment decisions (solely) on historical cultures. We were furthermore unable to irrefutably prove that, from a microbiological point of view, septic failure after 1-stage exchange comes with increased challenges. Given the time interval to failure, we propose that a longer follow-up of these patients is needed, than previously suggested.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2021.10.020 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!