Background: Hepatic encephalopathy (HE) is a complex neuropsychiatric syndrome associated with liver failure and/or portal systemic shunting. Polyethylene glycol (PEG) electrolyte solution is a commonly used for catharsis of gut, which has been demonstrated to relieve HE in a number of randomized controlled trials. The aim of this paper was to evaluate the comparative efficacy and safety of PEG with lactulose for current HE treatment.

Methods: PEG electrolyte solution versus lactulose of HE was deeply studied by conducting a systematic search in electronic databases and other sources until December 31, 2020. The PRISMA statement recommended the use of meta-analysis with 95% confidence interval (CI), relative risk (RR), and weighted mean deviation (WMD) as the estimated effect size. A sensitivity analysis was performed comprehensively to present the risk of bias and the source of heterogeneity.

Results: A total of 434 patients were involved in 7 randomized studies. It is found that there was a significant advantage of PEG therapy in the increase of clinical efficacy (RR=1.46; 95% CI: 1.26-1.68; P=0.000; I2=0.0%) and the decrease of hospital stay (WMD=-1.78; 95% CI: -2.72 to 0.85; P=0.000; I2=90.1%). There was no significant difference in the incidence of adverse events (RR=0.75; 95% CI: 0.48-1.19; P=0.222>0.05; I2=7.2%) and the level of serum ammonia (WMD=9.02; 95% CI: -14.39 to 32.43; P=0.45>0.05; I2=84.9%) after 24 hours between the 2 groups.

Conclusions: The results prove that PEG has a beneficial effect on the treatment of HE. Compared with lactulose, PEG can lead to more rapid HE resolution during the first 24 hours and shorten the length of stay without increasing the rate of adverse effects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8647701PMC
http://dx.doi.org/10.1097/MCG.0000000000001621DOI Listing

Publication Analysis

Top Keywords

electrolyte solution
12
polyethylene glycol
8
solution versus
8
versus lactulose
8
hepatic encephalopathy
8
peg electrolyte
8
peg
6
95%
5
comparative effectiveness
4
effectiveness safety
4

Similar Publications

Solid polymer electrolytes (SPEs) for symmetrical supercapacitors are proposed herein with activated carbon as electrodes and optimized solid polymer electrolyte membranes, which serve as the separators and electrolytes. We propose the design of a low-cost solid polymer electrolyte consisting of guanidinium nitrate (GuN) and poly(ethylene oxide) (PEO) with poly(vinylpyrrolidone) (PVP). Using the solution casting approach, blended polymer electrolytes with varying GuN weight percentage ratios of PVP and PEO are prepared.

View Article and Find Full Text PDF

The trace detection of pyocyanin (PCN) is crucial for infection control, and electrochemical sensing technology holds strong potential for application in this field. A pivotal challenge in utilizing carbon materials within electrochemical sensors lies in constructing carbon-based films with robust adhesion. To address this issue, a novel composite hydrogel consisting of multi-walled carbon nanotubes/polyvinyl alcohol/phosphotungstic acid (MWCNTs/PVA/PTA) was proposed in this study, resulting in the preparation of a highly sensitive and stable PCN electrochemical sensor.

View Article and Find Full Text PDF

Elevated dopamine (DA) levels in urine denote neuroblastoma, a pediatric cancer. Saccharide-derived carbon dots (CDs) were applied to assay DA detection in simulated urine (SU) while delineating the effects of graphene defect density on electrocatalytic activity. CDs were hydrothermally synthesized to vary graphene defect densities using sucrose, raffinose, and palatinose, depositing them onto glassy carbon electrodes (GCEs).

View Article and Find Full Text PDF

The importance of fluorine and aluminum in all aspects of daily life has led to an enormous increase in human exposure to these elements in their various forms. It is therefore important to understand the routes of exposure and to investigate and understand the potential toxicity. Of particular concern are aluminum-fluoride complexes (AlF), which are able to mimic the natural isostructural phosphate group and influence the activity of numerous essential phosphoryl transferases.

View Article and Find Full Text PDF

This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!