Synchrotron CT of an equine digit at the Australian Synchrotron Imaging and Medical Beamline.

J Synchrotron Radiat

Imaging and Medical Beamline, Australian Synchrotron (ANSTO), Wurundjeri Country, Clayton, VIC 3168, Australia.

Published: November 2021

Laminitis is an extremely painful and debilitating condition of horses that can affect their athletic ability and even quality of life. The current gold standard for assessment of laminar tissue is histology, which is the only modality that enables detailed visualization of the lamina. Histology requires dissection of the hoof and therefore can only represent one specific time point. The superior spatial and contrast resolution of synchrotron computed tomography (sCT), when compared with readily available imaging modalities, such as radiographs and conventional CT, provides an opportunity for detailed studies of the lamina without the need for hoof dissection and histological assessment. If the resolution of histology can be matched or even approached, dynamic events, such as laminar blood flow, could also be studied on the microscopic tissue level. To investigate this possible application of sCT further, two objectives are presented: (i) to develop a protocol for sCT of an equine digit using cadaver limbs and (ii) to apply the imaging protocol established during (i) for sCT imaging of the vasculature within the foot using an ex vivo perfusion system to deliver the vascular contrast. The hypotheses were that sCT would allow sufficient resolution for detailed visualization to the level of the secondary lamellae and associated capillaries within the equine digit. Synchrotron CT enabled good visualization of the primary lamellae (average length 3.6 mm) and the ex vivo perfusion system was able to deliver vascular contrast agent to the vessels of the lamina. The individual secondary lamellae (average length 0.142 mm) could not be seen in detail, although differentiation between primary and secondary lamellae was achieved. This approaches, but does not yet reach, the current gold standard, histology, for assessment of the lamellae; however, with further refinement of this imaging technique, improved resolution may be accomplished in future studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570209PMC
http://dx.doi.org/10.1107/S1600577521010493DOI Listing

Publication Analysis

Top Keywords

equine digit
12
secondary lamellae
12
current gold
8
gold standard
8
detailed visualization
8
vivo perfusion
8
perfusion system
8
system deliver
8
deliver vascular
8
vascular contrast
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!