Background: Transcatheter aortic valve replacement is an established treatment option for patients with severe symptomatic aortic stenosis and is most commonly performed through the transfemoral access route. Percutaneous access site closure can be achieved using dedicated plug-based or suture-based vascular closure device (VCD) strategies, but randomized comparative studies are scarce.

Methods: The CHOICE-CLOSURE trial (Randomized Comparison of Catheter-based Strategies for Interventional Access Site Closure during Transfemoral Transcatheter Aortic Valve Implantation) is an investigator-initiated, multicenter study, in which patients undergoing transfemoral transcatheter aortic valve replacement were randomly assigned to vascular access site closure using either a pure plug-based technique (MANTA, Teleflex) with no additional VCDs or a primary suture-based technique (ProGlide, Abbott Vascular) potentially complemented by a small plug. The primary end point consisted of access site- or access-related major and minor vascular complications during index hospitalization, defined according to the Valve Academic Research Consortium-2 criteria. Secondary end points included the rate of access site- or access-related bleeding, VCD failure, and time to hemostasis.

Results: A total of 516 patients were included and randomly assigned. The mean age of the study population was 80.5±6.1 years, 55.4% were male, 7.6% of patients had peripheral vascular disease, and the mean Society of Thoracic Surgeons score was 4.1±2.9%. The primary end point occurred in 19.4% (50/258) of the pure plug-based group and 12.0% (31/258) of the primary suture-based group (relative risk, 1.61 [95% CI, 1.07-2.44], =0.029). Access site- or access-related bleeding occurred in 11.6% versus 7.4% (relative risk, 1.58 [95%CI: 0.91-2.73], =0.133) and device failure in 4.7% versus 5.4% (relative risk, 0.86, [95% CI, 0.40-1.82], =0.841) in the respective groups. Time to hemostasis was significantly shorter in the pure plug-based group (80 [32-180] versus 240 [174-316] seconds, <0.001).

Conclusions: Among patients treated with transfemoral transcatheter aortic valve replacement, a pure plug-based vascular closure technique using the MANTA VCD is associated with a higher rate of access site- or access-related vascular complications but a shorter time to hemostasis compared with a primary suture-based technique using the ProGlide VCD. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04459208.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.121.057856DOI Listing

Publication Analysis

Top Keywords

pure plug-based
16
transcatheter aortic
16
aortic valve
16
primary suture-based
12
transfemoral transcatheter
12
valve replacement
12
access site
12
site closure
12
access site-
12
site- access-related
12

Similar Publications

Background: The location and severity of vascular calcification may influence closure device success in transfemoral transcatheter aortic valve implantation. The aim of this study was to analyze effects of vascular access-site calcification on vascular and bleeding outcomes post-transcatheter aortic valve implantation.

Methods: The Randomized Comparison of CatHeter-based Strategies fOr Interventional ACcess SitE CLOSURE during Transfemoral Transcatheter Aortic Valve Implantation (CHOICE-CLOSURE) trial assigned 516 patients to access site closure using a pure plug-based technique (MANTA, Teleflex) or a primary suture-based technique (ProGlide, Abbott Vascular).

View Article and Find Full Text PDF

Background: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a valuable treatment option for patients in cardiogenic shock, but complications during decannulation may worsen the overall outcome. Therefore, the aim of this study was to compare the efficacy and safety of suture-based to pure plug-based vascular closure devices for VA-ECMO decannulation.

Methods: In this retrospective study, the procedural outcome of 33 patients with suture-based closure devices was compared to 38 patients with MANTA plug-based closure devices.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement is an established treatment option for patients with severe symptomatic aortic stenosis and is most commonly performed through the transfemoral access route. Percutaneous access site closure can be achieved using dedicated plug-based or suture-based vascular closure device (VCD) strategies, but randomized comparative studies are scarce.

Methods: The CHOICE-CLOSURE trial (Randomized Comparison of Catheter-based Strategies for Interventional Access Site Closure during Transfemoral Transcatheter Aortic Valve Implantation) is an investigator-initiated, multicenter study, in which patients undergoing transfemoral transcatheter aortic valve replacement were randomly assigned to vascular access site closure using either a pure plug-based technique (MANTA, Teleflex) with no additional VCDs or a primary suture-based technique (ProGlide, Abbott Vascular) potentially complemented by a small plug.

View Article and Find Full Text PDF

Processing of nanolitre liquid plugs for microfluidic cell-based assays.

Sci Technol Adv Mater

December 2012

Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8573, Japan.

Plugs, i.e. droplets formed in a microchannel, may revolutionize microfluidic cell-based assays.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!