An electrochemical immunosensor for the detection of carcinoembryonic antigen based on Au/g-CN NSs-modified electrode and CuCo/CNC as signal tag.

Mikrochim Acta

Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, 832003, People's Republic of China.

Published: November 2021

AI Article Synopsis

Article Abstract

Carcinoembryonic antigen levels in the human body reflect the conditions associated with a variety of tumors and can be used for the identification, development, monitoring, and prognosis of lung cancer, colorectal cancer, and breast cancer. In this study, an amperometric immunosensor with CuCo/carbon nanocubes (CuCo/CNC) as the signal label is constructed. The bimetal-doped carbon skeleton structure has a high specific surface area and exhibits good electrocatalytic activity. In addition, Au/g-CN nanosheets (Au/g-CN NSs) are used to modify the substrate platform, facilitating the loading of more capture antibodies. The reaction mechanism was explored through electrochemical methods, X-ray powder diffraction, X-ray photoelectron spectroscopy, and other methods. Kinetic studies have shown that CuCo/CNC have good peroxidase-like activity. In addition, the electrocatalytic reduction ability of CuCo/CNC on hydrogen peroxide can be monitored using amperometric i-t curve (- 0.2 V, vs. SCE), and the response current value is positively correlated with the CEA antigen concentration. The prepared electrochemical immunosensor has good selectivity, precision, and stability. The dynamic range of the sensor was 0.0001-80 ng/mL, and the detection limit was 0.031 pg/mL. In addition, the recovery and relative standard deviation in real serum samples were 97.7-103 % and 3.25-4.13 %, respectively. The results show that the sensor has good analytical capabilities and can provide a new method for the clinical monitoring of CEA.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-021-05013-7DOI Listing

Publication Analysis

Top Keywords

electrochemical immunosensor
8
carcinoembryonic antigen
8
cuco/cnc signal
8
activity addition
8
immunosensor detection
4
detection carcinoembryonic
4
antigen based
4
based au/g-cn
4
au/g-cn nss-modified
4
nss-modified electrode
4

Similar Publications

Cancer Antigen 125 (CA125), is a high molecular weight mucinous glycoprotein found on the surface of ovarian cancer cells. Generally, 90 % of women may appear a high concentration of CA125 when they got the cancer; thus, CA125 can act as a marker for ovarian cancer diagnosis and therapeutic evaluation. COFs have been widely used for disease detection due to their structural stability, high loading capacity and biocompatibility.

View Article and Find Full Text PDF

Carbon dots in biosensing have advanced significantly, adding improvements to different detection techniques. In this study, an amperometric immunosensor for Salmonella Thyphimurium was designed using antibodies labeled with carbon dots (Cdots) from pequi almond (Caryocar brasiliensis). Cdots were synthesized by pyrolysis and characterized by FTIR, UV/fluorescence, electrochemistry, zeta potential, and transmission electron microscopy (TEM).

View Article and Find Full Text PDF

Trans-dimensional nanocoral gold foam interfaces affords ultrasensitive detection of influenza virus.

Anal Chim Acta

February 2025

School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan, 430065, PR China; Hubei Shizhen Laboratory, Wuhan, Hubei, 430065, PR China. Electronic address:

Development of sensitive and cost-effective strategies for detecting influenza viruses is crucial to combat the spread of infectious diseases. In this study, a novel trans-dimensional nanocoral gold foam (NCGF) was fabricated on screen-printed carbon electrodes using hydrogen template electrodeposition method. This unique structure, with interconnected large and small pores, significantly increased the specific surface area and stability of the sensor.

View Article and Find Full Text PDF

A Highly Sensitive Creatine Kinase Detection in Human Serum using 11-mercaptoundecanoic acid Modified ITO-PET Electrodes.

Anal Biochem

January 2025

Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale-TURKEY. Electronic address:

The enzyme creatine kinase (CK) is a biomarker that plays an extremely significant role in the early detection of cardiovascular disorders. Serum levels of CK are regularly monitored in patients with heart attacks, one of the most critical cardiovascular illnesses. In this study, a highly sensitive electrochemical immunosensor system was designed for the importance of early diagnosis of CK.

View Article and Find Full Text PDF

The importance of developing multifunctional nanomaterials for sensing technologies is increasing with the arrival of nanotechnology. In this study, we describe the introduction of novel nanoprobe electro-active material into the architecture of an electrochemical immuno-sensor. Based on the electrochemical immuno-sensor, functionalized tin oxide/graphitic carbon nitride nanocomposite (fSnO/g-CN) was synthesized and then analyte specific anti-aflatoxin M monoclonal antibody (AFM-ab) combined to form an electro-active nanoprobe (fSnO/g-CN/AFM-ab).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!