Comparison of pre- and post-surgical images of reusable and single use flexible ureteroscopes: a qualitative analysis.

Cent European J Urol

Department of Urology, Clínica RedSalud Vitacura, Santiago, Chile.

Published: September 2021

Introduction: Given the fragility of reusable ureterorenoscopes, many single use instruments have appeared on the market. Unfortunately, reuse of these scopes occurs in undeveloped countries in order to cut costs. This raises safety concerns for the patient.The aim of this article was to macroscopically evaluate the changes that single use flexible ureterorenoscopes (su-fURS) suffer after a retrograde intrarenal surgery (RIRS), and to compare them to reusable fURS.

Material And Methods: Pre and post-operative images of the instruments used in 23 RIRS were obtained. All the cases had renal calculi of the inferior calix between 10-15 mm, and all of them were treated with Holmium laser. The ureterorenoscopes used were: Storz Flex X2, Storz Flex XC, Pusen 3022, OTU Wiscope, AnQIng Innovex and Boston Scientific LithoVue. Qualitative comparisons of these were made.

Results: After su-fURS usage, significant damage was observed, especially on the distal tip. Deflection was not compromised. Reusable fURS did not sustain any damage after their use.

Conclusions: fURS are delicate equipment, especially if they are of single use. The considerable damage sustained by single use scopes could mean that reuse of these instruments is dangerous and should be avoided.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8552943PMC
http://dx.doi.org/10.5173/ceju.2021.0032.R2DOI Listing

Publication Analysis

Top Keywords

single flexible
8
storz flex
8
single
5
comparison pre-
4
pre- post-surgical
4
post-surgical images
4
reusable
4
images reusable
4
reusable single
4
flexible ureteroscopes
4

Similar Publications

Despite the availability of screening services, the rate of diabetic retinopathy (DR) screening continues to be suboptimal in Australia, necessitating improvement. However, improving DR screening rates requires a more comprehensive understanding of the factors influencing adherence to the screening recommendations. This study aimed to explore the factors that influence adherence to DR screening among people with diabetes attending a community screening clinic in Australia.

View Article and Find Full Text PDF

Fully Inkjet-Printed Flexible Graphene-Prussian Blue Platform for Electrochemical Biosensing.

Biosensors (Basel)

January 2025

University of Zagreb, Faculty of Chemical Engineering & Technology, Trg Marka Marulića 19, 10000 Zagreb, Croatia.

Prussian Blue (PB) is commonly incorporated into screen-printed enzymatic devices since it enables the determination of the enzymatically produced hydrogen peroxide at low potentials. Inkjet printing is gaining popularity in the development of electrochemical sensors as a substitute for screen printing. This work presents a fully inkjet-printed graphene-Prussian Blue platform, which can be paired with oxidase enzymes to prepare a biosensor of choice.

View Article and Find Full Text PDF

With the goal of fast and accurate diagnosis of infectious diseases, this study presents a novel electrochemical biosensor that employs a refined aptamer (C9t) for the detection of spike (S) protein SARS-CoV-2 variants in a flexible multielectrode aptasensor array with PoC capabilities. Two aptamer modifications were employed: removing the primer binding sites and including two dithiol phosphoramidite anchor molecules. Thus, reducing fabrication time from 24 to 3 h and increasing the stability and sparseness for multi-thiol aptasensors compared to a standard aptasensor using single thiols, without a reduction in aptamer density.

View Article and Find Full Text PDF

Adherence challenges are common among digital mental health interventions (DMHIs). Single-session DMHIs may help by providing a low-intensity intervention that takes less time to complete. This pilot randomized controlled trial sought to evaluate the acceptability and preliminary efficacy of a single-session DMHI based on acceptance and commitment therapy (ACT) in a non-clinical sample of college students.

View Article and Find Full Text PDF

Growth Propagation of Liquid Spawn on Non-Woven Hemp Mats to Inform Digital Biofabrication of Mycelium-Based Composites.

Biomimetics (Basel)

January 2025

Research Group Architectural Engineering, Department of Architecture, KU Leuven, 3001 Leuven, Belgium.

Mycelium-based composites (MBCs) are highly valued for their ability to transform low-value organic materials into sustainable building materials, offering significant potential for decarbonizing the construction sector. The properties of MBCs are influenced by factors such as the mycelium species, substrate materials, fabrication growth parameters, and post-processing. Traditional fabrication methods involve combining grain spawn with loose substrates in a mold to achieve specific single functional properties, such as strength, acoustic absorption, or thermal insulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!