A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Self-expanding metal ureteral stent for ureteral stricture: Experience of a large-scale prospective study from a high-volume center - Cross-sectional study. | LitMetric

Self-expanding metal ureteral stent for ureteral stricture: Experience of a large-scale prospective study from a high-volume center - Cross-sectional study.

Int J Surg

Department of Urology, Institute of Urology (Laboratory of Reconstructive Urology), West China Hospital, Sichuan University, Chengdu, Sichuan, PR China.

Published: November 2021

Background: The management of ureteral stricture is still a challenge for urologists. The aim of this prospective study was to assess the safety and effectiveness of self-expanding metal ureteral stents (URS) in ureteral strictures.

Methods: We performed URS placement procedures for ureteral stricture from Jan 2019 to July 2020, and prospectively collect various data before and after the operation. A paired T test was used to compare continuous variables before and after surgery, binary logistic regression analysis was used to identify the independent risk predictors of surgical failure.

Results: A total of 147 patients with 157 renal units received successful placement of URS. The mean operative time was 70.0 min. After a median follow-up time of 15 months, 73.2% (115/157) of stents were kept in situ. The most common complication was hematuria (13, 8.8%), followed by urinary tract infection (11, 7.5%) and pain (8, 5.4%). The volume of hydronephrosis (67.9 ± 34.9 VS 34.9 ± 51.1 cm, P = 0.0001), serum creatinine level (103.0 ± 54.5 VS 93.8 ± 45.1 μmol/L, P = 0.034) and blood urea nitrogen level (6.6 ± 6.7 VS 5.4 ± 2.4 mmol/L, P = 0.032) decreased significantly at last follow up when compared with baseline. Stricture of the distal ureter was an independent risk factor for stent failure (HR 1.77, 95% CI 1.15, 2.73, P = 0.009).

Conclusions: URS was found to be safe and effective for ureteral strictures with a limited complications and good long-term results. For those who are not suitable for surgical reconstruction, the URS is an alternative management.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijsu.2021.106161DOI Listing

Publication Analysis

Top Keywords

ureteral stricture
12
self-expanding metal
8
metal ureteral
8
prospective study
8
independent risk
8
ureteral
7
urs
5
ureteral stent
4
stent ureteral
4
stricture
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!