Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: There are only scarce data regarding the cardiovascular impact of arteriovenous fistula after kidney transplantation depending on fistula flow.
Methods: We performed a single-center, prospective, cohort study including 49 patients with a functional fistula at 1 year from kidney transplantation. Patients were convened for a clinical work-up, a biological analysis, a fistula's Doppler ultrasonography and an echocardiography. Main judgment criterion was comparison of echocardiography parameters between patients with relative (fistula flow >1 L/min and a fistula flow/cardiac output ratio >20%), absolute high-flow fistula (fistula flow >2 L/min) and normal-flow fistula.
Results: High-flow fistula frequency was 69%. Significantly higher left ventricular end-diastolic and systolic diameters were observed in this group compared with the normal-flow fistula group (53 ± 6 vs. 48 ± 7 mm; p = 0.04 and 33 ± 6 vs. 28 ± 8 mm; p = 0.02) and between the absolute and relative high-flow fistula subgroups (56 ± 6 vs. 51 ± 6 mm; p = 0.009 and 35 ± 6 vs. 31 ± 5 mm; p = 0.01). The study showed no other significant differences.
Conclusions: This study showed a significantly higher but not pathological left ventricular end-diastolic and systolic diameters values in patients with high-flow fistula compared with patients with normal-flow fistula and between patients with respectively absolute and relative high-flow fistula.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/sdi.13028 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!