A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Point-of-Care Glucose and Lipid Profile Measures Using a Human Point-of-Care Device in Mouse Models of Type 2 Diabetes Mellitus, Aging, and Alzheimer Disease. | LitMetric

A point-of-care (POC) device to measure mouse glucose and lipid profiles is an important unmet need for cost-effective, immediate decision making in research. We compared metabolic analyte profiles obtained using a human clinical POC device with those from a veterinary laboratory chemical analyzer (LCA). Unfasted terminal blood samples were obtained by cardiac puncture from C57Bl/6J mice used in a diet-induced obesity model of type 2 diabetes mellitus; age-matched C57Bl/6J controls; a transgenic mouse model of Alzheimer's disease on a C57BL/6J background (16 wk old); and aged C57BL/6J mice (24 to 60 wk old). Aliquots of the blood were immediately assayed onsite using the POC device. Corresponding serum aliquots were sent analyzed by LCA. Measures from the POC and LCA devices were compared by using the Bland-Altman and Passing-Bablok methods. Of a total of 40 aliquots, LCA results were within reported reference ranges for each model. POC results that fell beyond the device range were excluded from the analyses. The coefficient of determination and Passing-Bablok analysis demonstrated that POC glucose and HDL had the best agreement with LCA. The Bland-Altman analysis found no value-dependent bias in glucose and no significant bias in HDL. The remaining lipid analytes (cholesterol and triglyceride) showed significant bias. Until an improved, validated mouse POC device with lipid profile capability is available, the POC device that we tested appears adequate for screening glucose and HDL in mouse blood. Disadvantages of this clinical POC device are the narrow human ranges relative to ranges found in mice and its limited precision as compared with the LCA. This study demonstrates that when the samples are within the device range limits, this human POC device can accurately track metabolic syndrome and be used to compare patterns in glucose and HDL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628525PMC
http://dx.doi.org/10.30802/AALAS-JAALAS-21-000011DOI Listing

Publication Analysis

Top Keywords

poc device
28
glucose hdl
12
device
10
poc
10
glucose lipid
8
lipid profile
8
type diabetes
8
diabetes mellitus
8
clinical poc
8
c57bl/6j mice
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!