We present a calibration method for finding the coordinates of points in the trajectory of the scanning beam in flying-spot imaging devices. Our method is based on laterally translating the field of view on the imaging object plane by introducing additional beam deflections. We show that laterally translating the field of view provides a series of images whose relative translations are equal to the distances between the points in the scanning pattern to be calibrated. We show how these distances are mapped to the coordinates of the trajectory points. As an example, we demonstrate the calibration of the scanning patterns in an optical system with two independent microelectromechanical system based scanners. Our method profits from a large collection of distance measurements to find the trajectory coordinates, thereby minimizing the effect of random sources of uncertainty in the positions of points in the scanning pattern. We have found that we are capable of finding the coordinates of points in the scanning patterns with accuracy greater than the optical resolution of the imaging system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.431577 | DOI Listing |
Neurology
February 2025
Department of Neurology, John Hunter Hospital, Newcastle, Australia.
Adv Sci (Weinh)
January 2025
Department of Physics, University of Ulsan, Ulsan, 44610, Republic of Korea.
The anisotropic properties of materials profoundly influence their electronic, magnetic, optical, and mechanical behaviors and are critical for a wide range of applications. In this study, the anisotropic characteristics of Ni-based van der Waals materials, specifically NiTe and its alloy NiTeSe, utilizing a combination of comprehensive scanning tunneling microscopy (STM), angle-resolved photoemission spectroscopy (ARPES), and density functional theory (DFT) calculations, are explored. Unlike 1T-NiTe, which exhibits trigonal in-plane symmetry, the substitution of Te with Se in NiTe (resulting in the NiTeSe alloy) induces a pronounced in-plane anisotropy.
View Article and Find Full Text PDFNano Lett
January 2025
Materials Science and Technology Division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, Tennessee 37831, United States.
Thermally driven transitions between ferromagnetic and paramagnetic phases are characterized by critical behavior with divergent susceptibilities, long-range correlations, and spin dynamics that can span kHz to GHz scales as the material approaches the critical temperature , but it has proven technically challenging to probe the relevant length and time scales with most conventional measurement techniques. In this study, we employ scanning nitrogen-vacancy center based magnetometry and relaxometry to reveal the critical behavior of a high- ferromagnetic oxide near its Curie temperature. Cluster analysis of the measured temperature-dependent nanoscale magnetic textures points to a 3D universality class with a correlation length that diverges near .
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA, USA.
Purpose: To compare the assessment of clinically relevant retinal and choroidal lesions as well as optic nerve pathologies using a novel three-wavelength ultra-widefield (UWF) scanning laser ophthalmoscope with established retinal imaging techniques for ophthalmoscopic imaging.
Methods: Eighty eyes with a variety of retinal and choroidal lesions were assessed on the same time point using Topcon color fundus photography (CFP) montage, Optos red/green (RG), Heidelberg SPECTRALIS MultiColor 55-color montage (MCI), and novel Optos red/green/blue (RGB). Paired images of the optic nerve, retinal, or choroidal lesions were initially diagnosed based on CFP imaging.
Anal Methods
January 2025
Istanbul University, Faculty of Pharmacy, Department of Analytical Chemistry, 34116, Istanbul, Turkey.
In this study, a new reversed phase high performance liquid chromatography method using two detectors was developed for the analysis of degradation and process impurities of ivabradine in pharmaceutical preparations. A PDA detector set to 285 nm wavelength and a QDa detector set to positive scan mode were used in the method. In the developed method, the separation process was carried out in a Zorbax phenyl column with a gradient application of a 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!