Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Having an adequate supply of personal protective equipment during the COVID-19 pandemic has been a constant challenge for hospitals across the United States. In the event of shortages, our assembled mask might offer noninferior protection compared to an N95 respirator.
Objective: To study the ability of an assembled mask to pass a quantitative fit testing.
Methods: We conducted a feasibility study at the Oklahoma City Veteran Affairs Health Care System. Volunteers were fitted with an assembled mask made of either a Hans Rudolph half-face mask or a Respironics Performax full-face mask, attached to an Iso-Gard HEPA light Filter 28022 through a Performax SE elbow hinge. Quantitative fit testing was conducted using the Occupation Safety and Health Administration fit testing protocol. The primary outcome was the percentage of participants who pass the quantitative fit test. Secondary outcomes included the overall fit factor (FF), average FF for different exercises, changes in pulse oximetry and end-tidal CO at 0 and 15 minutes, willingness to use the mask, and visibility assessment.
Results: Twenty participants completed the study, and all (100 percent) passed the quantitative fit testing. The overall FF had a geometric mean of 2,317 (range: 208-16,613) and a geometric standard deviation of 3.8. The lowest FF was recorded while the subjects were talking. Between time 0 and 15 minutes, there was no clinically significant change in pulse oximetry and end-tidal CO levels. Most participants reported "very good" visibility and were "highly likely" to use the Hans Rudolph half-face mask in the case of shortage.
Conclusion: Our assembled respirator offers noninferior protection to N95 respirators in the setting of hypothetical protective equipment shortage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5055/jem.0611 | DOI Listing |