In France 58% of persons with hearing loss still do not wear hearing aids. Pure-tone audiometry is the traditional gold standard in assessment and screening of hearing impairment, but it requires the use of calibrated devices and soundproof booth. The antiphasic digits-in-noise (DIN) test does not require calibrated material and can run on a standard headset or earbuds connected to a smartphone or a computer. The DIN test is highly correlated with pure tone audiometry and has already shown to be effective in hearing loss screening in its English version promoted by the WHO. The aim of the present study was to develop and validate a French version of the antiphasic DIN test for implementation on a national screening test offered as a smartphone app. The audio files recorded from a French native female speaker were selected and normalized in intensity according to their recognition probability. The French DIN test application was then tested on normal hearing- and hearing-impaired subjects. Based on the strong correlation between pure tone audiometry (PTA) and DIN SRT, we calculated ROC curves and Z-score. For PTA > 20 dB HL, a SNR cutoff of 12.9 dB corresponds to a sensitivity and specificity of 0.96 and 0.93, respectively. To detect moderate and more severe hearing loss (PTA > 40 dB HL), the SNR cutoff was -10.9 dB, corresponding to a sensitivity and specificity of 0.99 and 0.83, respectively. The Z-score was calculated to define statistical criteria of normality for speech-in-noise evaluation. While a score of 0 roughly corresponds to the normality (DIN SRT = -15.4 dB SNR), a subject with DIN SRT > -12.2 (Z-score > 2) is ranked in the hearing loss population. Next, the French antiphasic DIN test was implemented in the Höra iOS and Android apps. In total, 19,545 Höra tests were completed and analyzed. Three quarters of them were classified as normal (74 %) and one quarter presented mild (9%) or more severe loss (17%). Together, results argue for the use of the French version of antiphasic DIN test in the general population to improve the screening of hearing-impaired individuals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8551565PMC
http://dx.doi.org/10.3389/fpubh.2021.725080DOI Listing

Publication Analysis

Top Keywords

din test
24
hearing loss
16
french version
12
version antiphasic
12
antiphasic din
12
din srt
12
din
9
antiphasic digits-in-noise
8
test
8
pure tone
8

Similar Publications

Objective: Measuring listening effort using pupillometry is challenging in cochlear implant (CI) users. We assess three validated speech tests (Matrix, LIST, and DIN) to identify the optimal speech material for measuring peak-pupil-dilation (PPD) in CI users as a function of signal-to-noise ratio (SNR).

Design: Speech tests were administered in quiet and two noisy conditions, namely at the speech recognition threshold (0 dB re SRT), i.

View Article and Find Full Text PDF

Background: Accurate measurement of blood pressure (BP) is crucial for the diagnosis and ongoing management of hypertension. Only devices that have been validated using an established protocol should be used to measure BP. The aim of this study was to validate the Microlife BP3T01-1B, an automated upper-arm BP measuring device, according to the DIN EN ISO 81060-2:2018-11 (ANSI/AAMI/ISO 81060-2:2018) standard protocol.

View Article and Find Full Text PDF

Background Heart failure (HF) is commonly managed by addressing water and sodium (Na) balance, with arterial circulation playing a major role in influencing renal Na and water excretion. Recently, chloride (Cl) has been recognized as an important factor in HF, associated with volume regulation and its modulation of renin-angiotensin-aldosterone system (RAAS) activity through macula densa signaling, which impacts Na retention and neurohormonal activation. Acetazolamide, a carbonic anhydrase inhibitor, can enhance decongestion in HF by increasing urinary Na and Cl excretion when added to loop diuretics, a mechanism supported by prior studies demonstrating improved urine output and decongestion.

View Article and Find Full Text PDF

Objective: To investigate the relationship between a history of otitis media (OM) in early childhood and speech reception thresholds (SRT) in later childhood, using the Dutch digits-in-noise (DIN) test at ages 9 and 13 years.

Methods: This study was conducted within the Generation R study, a prospective birth cohort in Rotterdam, the Netherlands. Children underwent pure-tone audiometry and DIN testing at ages 9 (2011-2015) and 13 (2016-2020) years.

View Article and Find Full Text PDF

Visual deficits/ametropia are particularly significant obstacles in sports because the visual system controls/corrects all of an athlete's movements. However, athletes are at increased risk for eye injuries caused by high-velocity objects e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!