Obtaining meaningful snapshots of the metabolome of microorganisms requires rapid sampling and immediate quenching of all metabolic activity, to prevent any changes in metabolite levels after sampling. Furthermore, a suitable extraction method is required ensuring complete extraction of metabolites from the cells and inactivation of enzymatic activity, with minimal degradation of labile compounds. Finally, a sensitive, high-throughput analysis platform is needed to quantify a large number of metabolites in a small amount of sample. An issue which has often been overlooked in microbial metabolomics is the fact that many intracellular metabolites are also present in significant amounts outside the cells and may interfere with the quantification of the endo metabolome. Attempts to remove the extracellular metabolites with dedicated quenching methods often induce release of intracellular metabolites into the quenching solution. For eukaryotic microorganisms, this release can be minimized by adaptation of the quenching method. For prokaryotic cells, this has not yet been accomplished, so the application of a differential method whereby metabolites are measured in the culture supernatant as well as in total broth samples, to calculate the intracellular levels by subtraction, seems to be the most suitable approach. Here we present an overview of different sampling, quenching, and extraction methods developed for microbial metabolomics, described in the literature. Detailed protocols are provided for rapid sampling, quenching, and extraction, for measurement of metabolites in total broth samples, washed cell samples, and supernatant, to be applied for quantitative metabolomics of both eukaryotic and prokaryotic microorganisms.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-0716-1585-0_2DOI Listing

Publication Analysis

Top Keywords

sampling quenching
12
rapid sampling
8
microbial metabolomics
8
intracellular metabolites
8
total broth
8
broth samples
8
quenching extraction
8
metabolites
7
quenching
6
fast sampling
4

Similar Publications

Desiccation tolerance is a complex phenomenon observed in the lichen Flavoparmelia ceparata. To understand the reactivation process of desiccated thalli, completely dried samples were rehydrated. The rehydration process of this lichen occurs in two phases.

View Article and Find Full Text PDF

In this study, 3,4-diaminobenzoic acid (DABA) was introduced into the porphyrin metal-organic framework (PCN-224) for the first time to prepare a ratiometric fluorescent probe (PCN-224-DABA) to quantitatively detect ferric iron (Fe(III)) and selenium (IV) (Se(IV)). The fluorescence attributed to the DABA of PCN-224-DABA at 345 nm can be selectively quenched by Fe(III) and Se(IV), but the fluorescence emission peak attributed to tetrakis (4-carboxyphenyl) porphyrin (TCPP) at 475 nm will not be disturbed. Therefore, the ratio of I/I with an excitation wavelength of 270 nm can be designed to determine Fe(III) and Se(IV).

View Article and Find Full Text PDF

detection suffers from slow analysis time and high costs, along with the need for specificity. While state-of-the-art electrochemical biosensors are cost-efficient and easy to implement, their sensitivity and analysis time still require improvement. In this work, we present a paper-based electrochemical biosensor utilizing magnetic core-shell FeO@CdSe/ZnS quantum dots (MQDs) to achieve fast detection, low cost, and high sensitivity.

View Article and Find Full Text PDF

A New Caffeine Detection Method Using a Highly Multiplexed Smartphone-Based Spectrometer.

Biosensors (Basel)

December 2024

Zhejiang University-University of Illinois Urbana-Champaign Institute, Zhejiang University, Haining 314400, China.

Smartphones equipped with highly integrated sensors are increasingly being recognized as powerful tools for rapid on-site testing. Here, we propose a low-cost, portable, and highly multiplexed smartphone-based spectrometer capable of collecting three types of spectra-transmission, reflection, and fluorescence-by simply replacing the optical fiber attached to the housing. Spectral analysis is performed directly on the smartphone using a custom-developed app.

View Article and Find Full Text PDF

Cardiovascular disease is the primary cause of mortality worldwide, as stated by the World Health Organization. We utilized the red fluorescence emitted by copper nanoclusters (CuNCs) to detect cardiac Troponin T (cTnT). We designed a fluorescent probe to detect cTnT using an on-off-on technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!