A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Midterm Outcomes for Polytetrafluoroethylene Valved Conduits. | LitMetric

Midterm Outcomes for Polytetrafluoroethylene Valved Conduits.

Ann Thorac Surg

Department of Cardiothoracic Surgery, Children's Hospital of Fudan University, Shanghai, China. Electronic address:

Published: November 2022

Background: Various conduits for right ventricular outflow tract reconstruction have been reported, but most of them are not available in China. The study investigators developed a simple handsewn valved conduit using expanded polytetrafluoroethylene (ePTFE). This study evaluated the midterm outcomes for this conduit.

Methods: This retrospective study included a total of 72 patients who underwent right ventricular outflow tract reconstruction with ePTFE valved conduits between January 2014 and June 2020. During follow-up, echocardiograms were performed for all patients, and magnetic resonance imaging was performed for patients with repaired tetralogy of Fallot.

Results: Patients had a median age of 69 months (interquartile range, 28-127 months) and a median follow-up period of 33 months (interquartile range, 9-51 months). There was no early death, but 2 late deaths (2.78%) occurred. The median conduit size was 18 mm (interquartile range, 18-20 mm) and the z score was +1.3 (interquartile range, +0.6-+2). Peak velocity across the ePTFE valve was 2.38 m/s (95% CI, 2.11-2.63 m/s). Pulmonary valve regurgitation was none or trivial in 27 (38.5%) patients, mild in 42 (60.0%) patients, and moderate in 1 (1.4%) patient. Conduit dysfunction occurred in 5 patients: 4 had moderate conduit stenosis, and 1 had moderate regurgitation. The right ventricular end-diastolic volume index in repaired tetralogy of Fallot was significantly decreased after surgery (171 mL/m vs 130 mL/m; P < .001). No reintervention or conduit replacement was needed.

Conclusions: This handsewn ePTFE valved conduit was associated with appreciable hemodynamic outcomes during the midterm follow-up period. Long-term follow-up studies are needed to corroborate these findings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2021.09.051DOI Listing

Publication Analysis

Top Keywords

interquartile range
12
midterm outcomes
8
valved conduits
8
ventricular outflow
8
outflow tract
8
tract reconstruction
8
performed patients
8
repaired tetralogy
8
months interquartile
8
patients moderate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!