Torsional properties of single fibers have considerable effects on the performance of fabrics. A new torsion tester with high resolution is developed based on the torsion-balance method and the autocollimation principle for measuring the torsional properties of single fibers. The tester can measure the torque accurately using the torsion wire of known torsional rigidity. The angular displacement of the torsion wire is measured by a non-contact electronic autocollimator. The calibration results show that the maximum torque capability is around 6 × 10 N m with a theoretical resolution of about 8 × 10 N m. The instrument's validity is verified by comparing the measurement result with that obtained by a torsion pendulum. Torsion tests on four industrially microfibers, including glass fiber, polyimide fiber, carbon fiber, and gold wire, are performed with the tester, which gives shear moduli 71.0 ± 0.4, 5.6 ± 0.1, 22.6 ± 3.1, and 34.3 ± 0.5 GPa, respectively. Young's moduli of these fibers are also provided. It is demonstrated that these fibers have a high anisotropy in mechanical properties.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0061349DOI Listing

Publication Analysis

Top Keywords

torsion tester
8
electronic autocollimator
8
torsional properties
8
properties single
8
single fibers
8
torsion wire
8
torsion
6
tester based
4
based electronic
4
autocollimator characterizing
4

Similar Publications

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

Oblique lateral interbody fusion (OLIF) is a minimally invasive surgery for the treatment of lumbar degenerative diseases (LDD). Under normal bone mass(NB), supplemental with lateral plate (LP) fixation has been proven to provide stability and reduce complications. However, it is unclear whether OLIF combined with LP fixation can achieve satisfactory fixation effects in cases of osteoporosis(OP) or osteopenia (OS)? In this study, Eighteen L3-5 spinal specimens from 3 to 6 months old fresh calves were equally divided into 3 groups: group A (NB), group B (OS) and group C (OP).

View Article and Find Full Text PDF

Background Context: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first-generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)-sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra-high-molecular-weight-polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed.

View Article and Find Full Text PDF

Study Design: A laboratory study comparing polyether ether ketone (PEEK)-zeolite and PEEK spinal implants in an ovine model.

Objective: This study challenges a conventional spinal implant material, PEEK, to PEEK-zeolite using a nonplated cervical ovine model.

Summary Of Background Data: Although widely used for spinal implants due to its material properties, PEEK is hydrophobic, resulting in poor osseointegration, and elicits a mild nonspecific foreign body response.

View Article and Find Full Text PDF

This study aimed to compare the torsional resistance of three fixation techniques for spiral metacarpal fractures: screw-only fixation, screw plus neutralization plate fixation, and a locking plate construct. A spiral fracture was created on 18 cadaveric metacarpal bones by applying an axial and torsional loading force using an Instron 3343 mechanical tester. The failure strength was defined as the native torque strength.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!