A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes. | LitMetric

Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes.

Braz J Otorhinolaryngol

Universidade Estadual de Campinas (UNICAMP), Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, Campinas, SP, Brazil.

Published: December 2022

Objectives: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome.

Methods: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light, the esophagus's anterior wall is visualized through the tracheostomy. A tracheoesophageal fistula is made with a blade and passed through the fistula. Then a bent trocar is introduced into the lumen using the device as a guidewire. Once in the lumen, a thin guide wire is passed through up to the mouth. The voice prosthesis is positioned with retrograde insertion. Then, the patient is discharged without hospitalization.

Results: 15 patients submitted to this technique had a successful surgical outcome. There were no complications as pneumothorax, esophageal perforation, bleeding, or hospitalization.

Conclusion: The new device is feasible under local anesthesia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756063PMC
http://dx.doi.org/10.1016/j.bjorl.2021.07.008DOI Listing

Publication Analysis

Top Keywords

secondary tracheoesophageal
8
tracheoesophageal puncture
8
flexible transillumination
8
transillumination device
8
voice prosthesis
8
local anesthesia
8
device
5
puncture flexible
4
device technique
4
technique outcomes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!