Effect of multiple firings on the shear bond strength of presintered cobalt-chromium alloy and veneering ceramic.

J Prosthet Dent

Assistant Professor, Dental Material Research Center, Department of Prosthodontics, Isfahan University of Medical Sciences, Isfahan, Iran.

Published: December 2021

Statement Of Problem: How multiple firing cycles may affect the oxide layer and, consequently, the shear bond strength of metal-ceramic restorations is unclear.

Purpose: The purpose of this in vitro study was to determine the effect of multiple firings on the shear bond strength of porcelain to cobalt-chromium (Co-Cr) alloy.

Material And Methods: Forty cylinders (Ø6.8×9 mm) of a representative presintered Co-Cr alloy (Ceramill Sintron) were prepared with computer-aided design and computer-aided manufacturing (CAD-CAM) technology. After airborne-particle abrasion and polishing, the specimens were ultrasonically cleaned of surface contaminants. A circular surface (Ø4×2 mm) was veneered on each specimen with porcelain (VM13) after 3 firings (wash opaque, opaque, and dentin). The specimens were then randomly divided into 4 groups (n=10). The normal group underwent 3 firings. The other groups underwent an additional porcelain firing: the one-plus firing group underwent 4 firings, the two-plus firing group underwent 5 firings, and the three-plus firing group underwent 6 firings. Next, the specimens were mounted in autopolymerized acrylic resin and tested in a universal testing machine and loaded at a crosshead speed of 0.5 mm/min at the metal-ceramic interface until fracture occurred. The average shear bond strength (MPa) was calculated by dividing the maximum fracture force (N) by the bonded surface of the specimens (mm). The fracture patterns were observed microscopically and classified as adhesive, cohesive, or mixed. One-way ANOVA was used to determine differences between groups (α=.05).

Results: No significant differences were found among the shear bond strengths of specimens after 3, 4, 5, and 6 porcelain firings (P>.05). The mean bond strength of all groups ranged from 30 to 34 MPa. The fracture pattern of all specimens was mixed, indicating that multiple firings had no significant effect on the failure pattern.

Conclusions: Multiple porcelain firings under controlled conditions had no significant effect on the fracture pattern or shear bond strength of porcelain to a presintered Co-Cr alloy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2021.09.021DOI Listing

Publication Analysis

Top Keywords

shear bond
24
bond strength
24
group underwent
16
underwent firings
16
multiple firings
12
firing group
12
firings
9
firings shear
8
strength porcelain
8
presintered co-cr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!