A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Vitrifying multiple embryos in different arrangements does not alter the cooling rate. | LitMetric

Vitrifying multiple embryos in different arrangements does not alter the cooling rate.

Cryobiology

Cardiff School of Mathematics, Cardiff University, Senghennydd Road, Cardiff, CF24 4AG, United Kingdom. Electronic address:

Published: December 2021

Vitrification is the most common method of cryopreservation of gametes in fertility clinics due to its improved survival rates compared to slow freezing techniques. For the Open Cryotop® vitrification device, the number of oocytes, or embryos, mounted onto a single device can vary. In this work, a mathematical model is developed for the cooling of oocytes and embryos (samples). The model is solved computationally, to investigate whether varying the number of samples mounted onto the Open Cryotop® affects the cooling rates, and consequently the survival rates, of vitrified samples. Several realistic spatial arrangements of samples are examined, determining their temperature over time. In this way we quantify the effect of spatial arrangement on the cooling rate. Our results indicate that neither the spatial arrangement nor the number of mounted samples has a large effect on cooling rates, so long as the volume of the cryoprotectant remains minimal. The time taken for cooling is found to be on the order of half a second, or less, regardless of the spatial arrangement or number of mounted samples. Hence, rapid cooling can be achieved for any number or arrangement of samples, as long as device manufacturer guidelines are adhered to.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cryobiol.2021.10.001DOI Listing

Publication Analysis

Top Keywords

spatial arrangement
12
cooling rate
8
survival rates
8
open cryotop®
8
oocytes embryos
8
cooling rates
8
arrangement number
8
number mounted
8
mounted samples
8
cooling
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!