Recent Developments of Intraoperative Neuromonitoring in Thyroidectomy.

Sisli Etfal Hastan Tip Bul

Department of General Surgery, University of Health Sciences Turkey, Sisli Hamidiye Etfal Training and Research Hospital, Istanbul, Turkey.

Published: September 2021

At present, intraoperative neuromonitorization (IONM) with surface electrode-based endotracheal tube (ETT) is a standard method in thyroidectomy and can be performed either intermittently IONM (I-IONM) or continuously IONM (C-IONM). Despite the valuable contribution of I-IONM to the thyroidectomy, it still has limitations regarding the recording electrodes and stimulation probe. New approaches for overcoming the limitations of I-IONM and developing the method are taking attention. Most of the technical issues of IONM with surface electrode-based ETT are related with inadequate contact of electrodes to the vocal cords. Nowadays, efficiency of various recording electrodes is under investigation. Recording electrodes such as needle electrodes applied to thyroarytenoid or posterior cricoarytenoid muscle (PCA), surface electrodes applied to the PCA, and needle or adhesive electrodes applied to the tracheal cartilage or skin, can make safe recordings similar to the ETT electrodes. Despite their invasiveness, needle electrodes record higher electromyography (EMG) amplitudes than tube electrodes do. Adhesive surface electrodes make safe EMG recordings, although amplitudes of these electrodes are usually lower than those of the tube electrodes. These different types of electrodes are less affected by tracheal manipulations and amplitude changes are lower compared to the tube electrodes. During C-IONM, an additional stimulation probe is applied to the vagus nerve after dissecting the nerve circumferentially. Recently, without applying a probe, a new continuous monitorization method called laryngeal adductor reflex CIONM (LAR-CIONM) using sensorial, central, and motor components of LAR arch which is an automatic, primitive brainstem reflex protecting the tracheoesophageal tree from foreign body aspiration, has been implemented. Afferent track of LAR communicates laryngeal mucosa to the brainstem by internal branch of the superior laryngeal nerve and efferent track reaches larynx through recurrent laryngeal nerve. Total outcome of LAR activation is the closure of laryngeal entry by bilateral vocal cord adduction. In LAR-CIONM, a stimulus is given by an electrode from one side of surface electrode-based ETT and amplitude response of the LAR at the vocal cord is followed on the operation side. Recently, it has been reported that real-time EMG response can be obtained with stimulation probe cables applied to dissectors or energy devices during the dissection through I-IONM.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8526228PMC
http://dx.doi.org/10.14744/SEMB.2021.26675DOI Listing

Publication Analysis

Top Keywords

electrodes
15
surface electrode-based
12
recording electrodes
12
stimulation probe
12
electrodes applied
12
tube electrodes
12
ionm surface
8
electrode-based ett
8
needle electrodes
8
surface electrodes
8

Similar Publications

Effect of sex on the levels of total arsenic (As) and As(III) in dog urine: a preliminary study.

Pol J Vet Sci

June 2024

Department of Animal Physiology and Physiotherapy, Faculty of Animal Breeding and Biology, Bydgoszcz University of Science and Technology, Mazowiecka 28, 85-084 Bydgoszcz, Poland.

The aim of the study was to analyze differences in the concentration of total arsenic (As) and As(III) in urine depending on the sex of mixed-breed dogs. Therefore, a research hypothesis was put forward that sex is a variable determining the degree and efficiency of urinary arsenic excretion. Two study groups were established: female (group 1) and male (group 2) mixed-breed dogs of similar body weight (9-13 kg) and aged 8-11 years.

View Article and Find Full Text PDF

Background: Patients with disorders of consciousness (DOC) undergoing spinal cord stimulation (SCS) for arousal treatment require an assessment of their conscious state before and after the procedure. This is typically evaluated using behavioral scales (CRS-R), but this method can be influenced by the subjectivity of the physician. Event-related potentials (ERP) and EEG power spectrum are associated with the recovery of consciousness.

View Article and Find Full Text PDF

Background: Long-term use of levodopa, a metabolic precursor of dopamine (DA) for alleviation of motor symptoms in Parkinson's disease (PD), can cause a serious side effect known as levodopa-induced dyskinesia (LID). With the development of LID, high-frequency gamma oscillations (~100 Hz) are registered in the motor cortex (MCx) in patients with PD and rats with experimental PD. Studying alterations in the activity within major components of motor networks during transition from levodopa-off state to dyskinesia can provide useful information about their contribution to the development of abnormal gamma oscillations and LID.

View Article and Find Full Text PDF

Alkaline Hydrogen Evolution Reaction Electrocatalysts for Anion Exchange Membrane Water Electrolyzers: Progress and Perspective.

JACS Au

December 2024

Shanghai Key Laboratory for R&D and Application of Metallic Functional Materials, Institute of New Energy for Vehicles, School of Materials Science and Engineering, Tongji University, 201804, Shanghai, China.

For the aim of achieving the carbon-free energy scenario, green hydrogen (H) with non-CO emission and high energy density is regarded as a potential alternative to traditional fossil fuels. Over the last decades, significant breakthroughs have been realized on the alkaline hydrogen evolution reaction (HER), which is a fundamental advancement and efficient process to generate high-purity H in the laboratory. Based on this, the development of the practical industry-oriented anion exchange membrane water electrolyzer (AEMWE) is on the rise, showing competitiveness with the incumbent megawatt-scale H production technologies.

View Article and Find Full Text PDF

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!