AI Article Synopsis

Article Abstract

The INHAND (International Harmonization of Nomenclature and Diagnostic Criteria for Lesions Project (www.toxpath.org/inhand.asp) is a joint initiative of the Societies of Toxicologic Pathology from Europe (ESTP), Great Britain (BSTP), Japan (JSTP) and North America (STP) to develop an internationally accepted nomenclature for proliferative and non-proliferative lesions in laboratory animals. The purpose of this publication is to provide a standardized nomenclature for classifying microscopic lesions observed in most tissues and organs from the laboratory rabbit used in nonclinical safety studies. Some of the lesions are illustrated by color photomicrographs. The standardized nomenclature presented in this document is also available electronically on the internet (http://www.goreni.org/). Sources of material included histopathology databases from government, academia, and industrial laboratories throughout the world. Content includes spontaneous lesions as well as lesions induced by exposure to test materials. Relevant infectious and parasitic lesions are included as well. A widely accepted and utilized international harmonization of nomenclature for lesions in laboratory animals will provide a common language among regulatory and scientific research organizations in different countries and increase and enrich international exchanges of information among toxicologists and pathologists.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544166PMC
http://dx.doi.org/10.1293/tox.34.183SDOI Listing

Publication Analysis

Top Keywords

international harmonization
12
harmonization nomenclature
12
lesions
9
nomenclature diagnostic
8
diagnostic criteria
8
lesions laboratory
8
laboratory animals
8
standardized nomenclature
8
nomenclature
6
international
4

Similar Publications

Based on nitrogen and phosphorus co-doped carbon dots (NP-CDs), a direct, quick, and selective sensing probe for fluorometric detection of rutin has been developed. Utilizing ethylene diamine tetra acetic acid (EDTA) as a carbon and nitrogen source and diammonium hydrogen phosphate (NH)HPO as a nitrogen and phosphorus source. The NP-CDs were synthesized in less than 3 min with a straightforward one-step microwave pyrolysis process with a high quantum yield (63.

View Article and Find Full Text PDF

Introduction: The optimal treatment for recurrent glioblastoma patients remains not well-defined in international guidelines. On top of that, the availability of national guidelines is uncharted.

Research Question: This study aimed to investigate the availability of national guidelines on the diagnosis and treatment of adult glioma throughout Europe, specifically focusing on recurrent glioblastoma.

View Article and Find Full Text PDF

Highly sensitive spectrofluorimetric methods were developed for the quantitative estimation of formoterol fumarate dihydrate (FFD) and fluticasone propionate (FP) in both authentic raw materials and marketed dosage forms using a micellar-enhanced spectrofluorimetric approach. The proposed methods are based on the determination of FP in the presence of FFD using the first derivative emission spectrofluorimetry. The peak amplitude of the emission spectra of the formed micellar fluorescence was measured at 465 nm after excitation at 236 nm (λ max of FP).

View Article and Find Full Text PDF

In this submission we opine on India adopting a rather stringent maximum single year dose limit, instead of harmonizing with international standards. We explore how dose limits evolved, why India has opted for a lower maximum effective dose limit of 30 mSv for a single year and argue that raising this limit to at least 50 mSv, in line with International Commission on Radiological Protection (ICRP) recommendations, would not only contribute to upcoming revised ICRP publications but also support the realization of India's nuclear ambitions.

View Article and Find Full Text PDF

Lidocaine poses challenges when it comes to direct spectrophotometric measurement due to the lack of sharp peak within its spectra in zero-order. This lack of a distinct peak makes it difficult to accurately quantify lidocaine using traditional direct spectrophotometric methods. In our study, different univariate and multivariate spectrophotometric techniques have been established and their validity has been assessed for the determination of the mixture of Lidocaine HCl (LD), Oxytetracycline HCl (OTC) together with LD carcinogenic impurity [2,6- dimethylaniline] DMA.